Hampton Direct HI300 installation manual Maintenance

Page 16

MAINTENANCE

DOOR GASKET

If the door gasket requires replacement, 7/8" diameter material must be used.Aproper high temperature gasket adhesive is required. A gasket repair kit, Part # 846-570 is available from your local Hampton dealer.

GLASS CLEANING

Only clean your glass window when it is cool. Your local retailer can supply you with special glass cleaner if plain water and a soft cloth does not remove all deposits.

DOOR REMOVAL

Whenhandlingenamelparts,pleasehandle with care as they can be damaged.

1)Remove the Top Faceplate by lifting straight up from the sides.

2)Lift off Mantel Top.

3)Open the Door and lift up off its hinges.

Please be careful when removing the Door and not to drop onto the Ashlip, it may chip.

Hinges

Door

GLASS

REPLACEMENT

1)Remove door from unit.

2)To replace the glass remove the 8 screws highlighted in the diagram below.

3)Lift off the glass retainer and carefully remove glass.

4)Place new glass in the door, make sure that the glass gasketing will properly seal your unit.

5)Position the glass retainer back on. Ensure that it rests on the gasket and not the glass.

6)Secure glass retainer using the 8 screws. Do not wrench down on the glass as this may cause the glass to break.

7)Place door back on unit.

Remove 8 screws.

Avoid impact on glass doors such as striking or slamming shut.

HANDLE

REPLACEMENT

1)Remove handle by undoing the hex head bolt using a 7/16" socket wrench.

2)Fit new door handle over latch and se- cure.

Assemble handle by:

a)Placing lock washer over hex head bolt.

b)Place hex head bolt into handle.

c)Place spacer over hex head bolt threads.

d)Screw handle into door latch.

Spacer

Handle

Hex Head

LockBolt

Washer

DOOR INSTALLATION NOTE

After re-installing the door, carefully swing open and check the clearance to the Right Hand Cast Side. If tight or rubbing, loosen the 7/16 nuts and adjust the clearance and then re-tighten.

16

Hampton HI300 Wood Cast Insert

Image 16
Contents Wood Cast Insert Hampton Fireplace Product Table of Contents Safety Label Safety Label for HI300Unit Dimensions Installation Before Installing Your InsertChimney Specifications Wood Insert SpecificationsMasonry and Factory Built Fireplace Clearances Step bOptional Flue Connector KIT Installing Your InsertFlue Connector Bracket Installation Into a Masonry Fireplace Installation Into a Factory Built FireplaceCast Faceplate Installation Backside of Unit ShownLocation of Insulations FAN Installation Do not Route Power Cord Under Or in Front of UnitFlue Baffle Secondary AIR Tube Installation Firebrick AssemblyDraft Control Operating Instructions Safety GuidelinesFirst Fire Creosote Wood Storage ASH DisposalMaintenance Latch Adjustment Mounting Bracket Latch Assembly Spacers Removed from unitParts List HI300 Main AssemblyHI300 Cast Faceplate HI300 Brick Panels Hampton HI300 Wood Cast Insert Hampton HI300 Wood Cast Insert Warranty ConditionsInstaller Please complete the following information