Vulcan-Hart VCRB36, VCRB47, VCRB25 operation manual Operation, Controls, Lighting the GAS Pilot

Page 8

OPERATION

The charbroiler and its parts are hot. Use care when operating, cleaning or servicing the charbroiler.

CONTROLS

Fig. 5

OFF

ON

 

 

CONTROL KNOBS

Each burner is independently controlled by an infinite heat control valve. Once the pilots are lit, turning the control knob to the ON position will light each burner. The burners will be in the full ON position when the control knobs are turned all the way to the left. The burners will be in the full OFF position when the control knobs are turned all the way to the right. See Fig. 5.

There is one pilot for each burner. The charbroiler is equipped with standing, unmonitored pilots. Gas will flow from the pilots as soon as the main gas supply to the unit is turned on. See pilot lighting procedure on page 8.

Standing pilots should be adjusted to provide a slight yellow tip on the flame. Air shutters on the main burners must be individually adjusted to provide a blue flame. All traces of yellow should be adjusted out of the burner flame.

The charbroiler is a free vented appliance. All products of combustion and the heat generated by the burners pass through the grates. When meat is placed on the grates, this blocks the venting and causes a temperature build-up.

LIGHTING THE GAS PILOT

1.See Fig. 6. Turn main gas shut‐off valve and the individual burner gas valves OFF. Wait 5 minutes.

2.Remove the top grates and radiants. Turn the main gas shut‐off valve ON. Light pilots using a lit taper .Adjust the pilot valve screw (See Fig. 7 on page 9)until the pilot flame has a

a slight yellow tip.

3.To light the burners, turn the individual burner valves ON.

4.If the burners fail to light, turn all valves and the main gas shut‐off

to the OFF position and contact an

FIG. 6

authorized service agency.

 

Pilots

- 8 -

Image 8
Contents Models VCRB47Retain this Manual for Future USE Important for Your Safety For Your SafetyInstallation UnpackingInstallation Codes and Standards Location Ventilation Hood BURNERS, RADIANTS, and TOP Grates Leveling GAS Pressure Regulator Installation GAS ConnectionPropane GAS Conversion Caster Equipped CharbroilersLighting the GAS Pilot OperationControls Pilot Adjustment To Completely Shutdown the Burners and Pilot LightsPreheating the Charbroiler Component PartsMaintenance CleaningService Vent SystemTroubleshooting Page Modèles Sécurité Votre Pour Sécurité Votre Pour ImportantDéballage BTU/h calorifique Débit Brûleurs de Nombre Modèle’INSTALLATION Normes ET Codes EmplacementSupérieures Grilles ET Radiants Brûleurs Ventilation DE HotteNiveau À Mise GAZ DU Pression DE Régulateur DU Installation GAZ DU ConnexionRoulettes DE Munis Grils Propane GAZ DU ConversionCommandes Emploi’ALLUMAGE Veilleuse LA DE Réglage ComposantsGril DU Préchauffage Entretien LubrificationVentilation DE Système NettoyageDépannage Remarques