Vulcan-Hart VCRB47, VCRB25 Pilot Adjustment, To Completely Shutdown the Burners and Pilot Lights

Page 9

PILOT ADJUSTMENT

Using a flathead screwdriver, turn the slotted hex-head pilot adjustment screw clockwise to decrease the flame, and counterclockwise to increase the flame. See Fig. 7.

Fig. 7

TO COMPLETELY SHUTDOWN THE BURNERS AND PILOT LIGHTS

For complete shutdown: Turn the main gas shut-off valve OFF. (Make sure all individual burner valves are off before relighting.)

PREHEATING THE CHARBROILER

Allow the charbroiler to preheat for 30 minutes. Rub grates with cooking oil before using.

COMPONENT PARTS

The charbroiler comes with several standard parts as illustrated. Each can be easily removed and installed easily by hand for cleaning and maintenance. Note that the Burner and Deflector are an assembly and are NOT designed to be disassembled.

- 9 -

Image 9
Contents VCRB47 Retain this Manual for Future USEModels For Your Safety Important for Your SafetyUnpacking InstallationLocation Installation Codes and StandardsBURNERS, RADIANTS, and TOP Grates LevelingVentilation Hood GAS Connection GAS Pressure Regulator InstallationCaster Equipped Charbroilers Propane GAS ConversionOperation ControlsLighting the GAS Pilot To Completely Shutdown the Burners and Pilot Lights Pilot AdjustmentPreheating the Charbroiler Component PartsCleaning MaintenanceService Vent SystemTroubleshooting Page Modèles Sécurité Votre Pour Important Sécurité Votre PourBTU/h calorifique Débit Brûleurs de Nombre Modèle DéballageEmplacement ’INSTALLATION Normes ET CodesVentilation DE Hotte Niveau À MiseSupérieures Grilles ET Radiants Brûleurs GAZ DU Connexion GAZ DU Pression DE Régulateur DU InstallationPropane GAZ DU Conversion Roulettes DE Munis GrilsEmploi CommandesComposants Gril DU Préchauffage’ALLUMAGE Veilleuse LA DE Réglage Lubrification EntretienVentilation DE Système NettoyageDépannage Remarques