Nexgrill 720-0439 operating instructions Leak Testing, General

Page 15

LEAK TESTING

GENERAL

Although all gas connections on the grill are leak tested at the factory prior to shipment, a complete gas tightness check must be performed at the installation site due to possible mishandling in shipment, or excessive pressure unknowingly being applied to the unit. Periodically check the whole system for leaks following the procedures listed below. If the smell of gas is detected at anytime you should immediately check the entire system for leaks.

BEFORE TESTING

Make sure that all packing material is removed from the grill including the burner tie-down straps.

DO NOT SMOKE WHILE LEAK TESTING.

NEVER PERFORM LEAK TEST WITH AN OPEN FLAME.

Make a soap solution of one part liquid detergent and one part water. You will need a spray bottle, brush, or rag to apply the solution to the fittings. For the initial leak test, make sure the L.P. cylinder is full.

TO TEST

1.Make sure the control valves are in the “OFF” position, and turn on the gas supply.

2.Check all connections from the LP gas regulator and supply valve up to and including the connection to the manifold pipe assembly (the pipe that goes to the burners). Soap bubbles will appear where a leak is present.

3.If a leak is present, immediately turn off the gas supply and tighten the leaky fittings.

4.Turn the gas back on and recheck.

5.Should the gas continue to leak from any of the fittings, turn off the gas supply and contact customer service at 1-866-984-7455.

Only those parts recommended by the manufacturer should be used on the grill.

Substitution will void the warranty. Do not use the grill until all connections have been checked and do not leak.

GAS FLOW CHECK

Each grill burner is tested and adjusted at the factory prior to shipment; however, variations in the local gas supply may make it necessary to adjust the burners. The flames of the burners should be visually checked.

Flames should be blue and stable with no yellow tips, excessive noise or lifting. If any of these conditions exist, check to see if the air shutter or burner ports are blocked by dirt, debris, spider webs, etc. If you have any questions regarding flame stability, please call customer service 1-866-984-7455 .

ALWAYS CHECK FOR LEAKS AFTER EVERY L.P. TANK CHANGE

Check all gas supply fittings for leaks before each use. It is handy to keep a spray bottle of soapy water near the shut-off valve of the gas supply line. Spray all the fittings. Bubbles indicate leaks.

J19Y06P-1 11

Image 15
Contents Assembly & Operating Instructions Importance Message to OUR ConsumersTable of Contents California Proposition 65-WARNING PrecautionsPrecautions Do not USE Briquettes of ANY Kind in the Grill Placement of the GrillAssemblysembleinstructions Assembly Instructions Assembly Instructions Cylinder Tank Fixed Assembly Instructions To Match Light the Grill Tank Requirement GAS HOOK-UPUSER, Please Retain this Manual for Future Reference Installer Final Check ListGeneral Leak TestingYour grill is ready to use General USE of the Grill and Rotisserie Operating InstructionsGrill Lighting Instructions To Light the Side Burner Grill Lighting Instructions Flame Characteristics Burner Lighting IllustrationStainless Steel Care and MaintenanceHOW to Replace Main Burner Spider and Insect Warning Trouble ShootingTrouble Shooting Problem Solution Too much or not enough air mixes for the flame Exploded View REF# Description QTY Parts ListParts List Grill Hints Ordering PartsMeats Grill Cooking ChartPoultry Fish Seafood BBQ Salmon Grill Recipe SuggestionsVegetable Kabobs Chicken Tandoori Style Converting to Natural GAS 720/730-0439 Instructions for Converting to Natural GAS GAS Conversion Side Burner Conversion Rear Burner Conversion For Main tube burner and Side burner Conversion Only NG Hose and Regulator Conversion J19Y06P-1 Stainless Steel Outdoor GAS Grill Limited Warranty