9
OPERATION / MAINTENANCE
If heater keeps shutting off, have it serviced. Keep burner and control compartment clean.
When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the curing of the logs and the
FOR YOUR SAFETY READ BEFORE LIGHT-
A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly.
B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor.
C. Use only your hand to turn the gas control knob / manual
D. Do not use this fireplace if any part has been under water. Im- mediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under water.
WHAT TO DO IF YOU SMELL GAS
•Do not use a mobile or land phone.
•If you cannot reach your gas supplier, call the fire department.
•Turn off all gas to the fireplace.
•Do not try to light any appliance.
•Immediately call your gas supplier from a
neighbour’s phone. Follow the gas supplier’s instructions.
After extended periods of
LIGHTING INSTRUCTIONS
When lighting and
1.Stop! Read the safety information on the operating label.
2.Turn the gas knob clockwise to off.
3.Wait five (5) minutes to clear out any gas. If you smell gas including near the floor, stop! Follow “b” on the operating label. If you don’t smell gas go to the next step.
4.If fireplace is equipped with flame adjustment valve turn clockwise to off.
5.Find pilot located in front of back log.
6.Turn gas knob
7.Depress and hold gas knob while lighting the pilot with the push button igniter. Keep knob fully depressed for one minute, then release. If pilot does not continue to burn repeat steps 3 through 7.
8. With pilot lit, turn gas knob | t | o |
on. |
|
|
9.If equipped with flame adjustment valve, push and turn knob to high.
10.If equipped with remote
TO TURN OFF GAS
•Push in gas control knob slightly and turn clockwise to off. Do not force.
MAINTENANCE
CAUTION: Label all wires prior to disconnection when servic- ing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. This heater should be inspected and serviced before use and at least an- nually by a qualified service person. The fireplace area must be kept clear and free of combustible materials, gasoline or other flammable vapours and liquids. The flow of combustion and ventilation air must not be obstructed.
2.Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacuum- ing or brushing, at least once a year.
3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burn- ing properly.
4.Check to see that the pilot flame is large enough to engulf the thermocouple and thermopile and promptly ignites the main burner.
6.Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5 to
10second total
Cleaning Stainless Steel: Do not use abrasive cleaners to clean any painted, porcelain or stainless steel parts. To clean stainless surfaces, use a stainless steel cleaner or a non- abrasive cleaner. Always wipe in the direction of the grain.
Do not use steel wool, as it will scratch the finish. Stainless steel parts will discolour when heated, usually to a golden or brown colour. This discolouration is normal and will not affect the performance of the appliance.
VENTURI ADJUSTMENT
Air shutter adjustment must only be done by a quali-
fied gas installer!
Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established. Opening the air shutter will also reduce exhaust odours. See Trouble Shooting Guide.
AIR SHUTTER
OPENINGS
NG | 3/16” | FIGURE 16 |
LP | 1/4” |
|