Desa (V)TC36NE Series, (V)TC36GPE Series installation manual Location of Termination CAP

Page 6

6

LOCATION OF TERMINATION CAP

LOCATION OF TERMINATION CAP

D

E V

B L

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fixed

 

V

 

 

 

 

 

 

Closed

 

 

 

 

 

 

 

 

 

F

 

 

V

 

Openable

 

 

 

 

 

 

 

 

 

 

 

 

 

B

B

B

Openable Fixed Closed

H

V

B

I

V J XG

AM

NN

 

G

 

V

 

G

V K X

V

 

A

V TERMINATION CAP

X AIR SUPPLY INLET

G GAS METER

RESTRICTED AREA (TERMINATION PROHIBITED)

A= clearance above grade, veranda, porch, deck, or balcony [*12 inches (30.5mc) minimum]

B= clearance to window or door that may be opened [12 inches (30.5cm) minimum]

C = clearance to permanently closed window [minimum 12 inches (30.5cm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 inches (61cm) from the center-line of the terminal [18 inches (45.7cm) minimum]

E= clearance to unventilated soffit [12 inches (30.5cm) minimum] F = clearance to outside corner (see below)

G = clearance to inside corner (see below)

H = *not to be installed above a meter/regulator assembly within

36 inches (91.4cm) horizontally from the center-line of the regulator

I= clearance to service regulator vent outlet [*72 inches (182.9cm) minimum]

J= clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12 inches (30.5cm)

minimum]

K= clearance to a mechanical air supply inlet [*72 inches (182.9cm) minimum]

L= † clearance above paved side-walk or a paved driveway located on public property [*84 inches (213.3cm) minimum]

M = clearance under veranda, porch, deck [*12 inches (30.5cm) minimum ‡]

N= clearance above a roof shall extend a minimum of 24 inches (61cm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (45.7cm)

† vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*

only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.

Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner

Outside Corner

Recessed Location

AA = 6" (15.2cm)

V

Balcony with No Side Wall

G

V

G = 12" (30.5cm) minimum clearance

V

B B = 6" (15.2cm)

Balcony with Perpendicular Side Wall

H

V

J

Combustible &

Noncombustible

H = 24" (61cm)

J = 20" (50.8cm)

 

D

C

C

E

V

C = Maximum depth of 48" (121.9cm) for recessed location

D = Minimum width for back wall of recessed location - Combustible - 38" (965mm) Noncombustible - 24" (61cm)

E = Clearance from corner in recessed location- Combustible - 6" (15.2cm) Noncombustible - 2" (5.1cm)

Figure 7 - Minimum Clearances for Termination Cap

www.desatech.com

116234-01A

Image 6
Contents For Your Safety For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Product Identification Local CodesProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Vent ClearancesFraming and Finishing Specific venting clearancesLocation of Termination CAP Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsMale Female Slots Locking Lugs Installation PlanningHorizontal Termination Installation CenterHorizontal Vent Cap Wood ScrewInterior Wall Surface Firestop Vent Cap Vent PipeHorizontal Termination Configurations Recommended Applications Corner ground floor installation Over 12 horizontal pipeTermination is possible Venting with Two 90 Elbows Connect a section of pipe and extend up through the hole Installation for Vertical TerminationFlat Ceiling Installation Roof Flashing Wall Strap Elbow Ceiling FirestopVertical Termination Configurations Elbow Into inner collar fireplace as shownHigh Altitude Installation Installing Optional Blower Accessory Venting InstallationFireplace Installation Check GAS Type Desa 5/8 Pipe & Vent KitsBy turning knob fully counterclockwise before continuing Fireplace InstallationModel BKT Installation Decal on the firebox bottom approximately 12 in frontInstalling GAS Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Connecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Removing Louver Panels Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Bubbles forming show a leak. Correct all leaks at onceInstalling Lava Rock and Glowing Embers Cleaning Glass DoorRemoving Glass Door Optional Remote Control Installing Brick Liner Models BL36DASA and BL36DHASAWall Switch Installation Extension Cord IgnitionLighting Instructions Wiring DiagramOperating Fireplace Equipment PilotOptional Remote Operating Optional Blower AccessoryTo Turn OFF GAS To Appliance OperationPilot and Burners Cleaning MaintenanceGlass Door LogsTroubleshooting Improper vent configuration PositionBL36DHASA for log/grate removal Restrictions or obstructionTechnical Service Replacement PartsService Hints Parts Under WarrantySpecifications Illustrated Parts Breakdown Models TC36NE, VTC36NE, TC36PE and VTC36PEParts List KEY Part Number TC36NE/PE VTC36NE/PE Description QTY19 18 2827 116234-01A KEY Part Number Description Accessories Brand ModelDate Purchased Serial Number Industrial Drive Box Bowling Green, KY 116234-01A Warranty Information Model Serial No Date PurchasedIndustrial Drive P.O. Box