Desa (V)K42P SERIES Optional HAND-HELD Remote Operation, Thermostat Series Models Ghrctb

Page 25

OPERATING FIREPLACE

Optional Hand-Held Remote Operation

25

OPERATING FIREPLACE

Continued

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be purchased sepa- rately (see Accessories, page 36). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instruc- tions, page 24.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 51). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

THERMOSTAT SERIES MODELS GHRCTB

Thehand-heldremotecanbeoperatedusingeitherthemanualmode (MANU) or thermostatic mode (AUTO) (see Figure 53). To select Fahrenheit/Centigrademodedisplay,carefullypressthe˚C/˚Fmode button with the end of a paper clip or similar blunt object.

Manual Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press the MANU button to turn on the fireplace.

3.Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press AUTO button to select this mode.

3.Set the desired room temperature by pressing the TEMP + or - buttons.

4.Press the POWER and LOCK buttons together to turn off the fireplace

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the

Blower Control Knob

(Optional Accessory)

Gas Control

Knob in ON

Position Variable

Control Knob

center of the room facing towards the fireplace.

Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.

Selector

OFF

ON

Switch in

 

Remote

ON OFF REMOTE

Position

 

N

 

L

 

O

 

O

I

T

F

O

H

O

 

 

F

 

 

LIP

 

 

 

 

 

 

 

Digital Display

Shows

Temperature and

Settings

Turns Hand-Held Remote On or Off and Allows You to Choose the Manual Setting

Figure 51 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation

ON/OFF SERIES MODELS GHRCB

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 52).

TO LOCK press both buttons on hand-held remote control until light stops flashing. Hand-held remote control is now locked. If the fire is on it will be turned off automatically. In the locked

Turns Burners On or Off

Decreases Room

Temperature in

AUTO Mode

Selects Auto

Setting

Increases Room

Temperature in

AUTO Mode

Locks System to Prevent Accidental Ignition

state, the light will not light up when any button is pressed.

TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

Control Button

Turns Burners

On and Off

Figure 52 - On/Off Hand-Held Remote Control Unit GHRCB

Figure 53 - Thermostat Hand-Held Remote Control Unit Selections GHRCTB

Safety Features

When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fire- place, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Auto Shutoff Feature

1.If the average room temperature exceeds 82 degrees Fahr- enheit (28 degrees Centigrade), the hand-held remote con- trol will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

For morevisit www..com

111921-01D

Image 25
Contents For Your Safety OWNER’S Operation Installation ManualFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Product IdentificationPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationNumber Description Installing Optional Blower Accessories Fireplace InstallationModel BK Installation Check GAS TypeBlower Model BKT Model BKT InstallationBlower Wiring Diagram Installing GAS Piping to Fireplace LocationInstallation Items Needed Installation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2REMOVING/REPLACING Glass Door Installing Remote ReceiverRemoving Louver Panels Cleaning Glass Door Installing Brick Liner Models BL42DASA and BL42DHASARemoving Glass Doors Crossover log onto logs #4 and #5 as shown in Figure Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsThermostat Series Models Ghrctb Optional HAND-HELD Remote OperationON/OFF Series Models Ghrcb Pilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementService Hints Replacement PartsTechnical Service SpecificationsModels Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListBurner Assembly for Models VK42N, VK42NH, VK42P, VK42PH Parts List Accessories Owners Registration Form For Com 111921-01D Warranty Information