Desa (V)K42P SERIES installation manual REMOVING/REPLACING Glass Door, Installing Remote Receiver

Page 21

FIREPLACE INSTALLATION

Installing Optional Wireless Hand-Held Remote Control - GHRCB and GHRCTB Series Removing/Replacing Glass Door

21

FIREPLACE INSTALLATION

Continued

INSTALLING OPTIONAL WIRELESS HAND- HELD REMOTE CONTROL - GHRCB AND GHRCTB SERIES

NOTICE: Use only alkaline batteries (not included).

Installing Remote Receiver

1.Open bottom louver and locate the switch bracket on the left.

2.Unscrew the switch bracket. Lean bracket forward so you are able to access the back of the remote receiver.

3.Locate the battery clip mounted on the back of the receiver. Slide a 9-volt alkaline battery (not included) through the clip (see Figure 37, page 21).

4.Attach the terminal wires to the battery.

5.Connect wires from receiver to TH and TPTH to control valve (see Figure 38).

6.Replace the switch bracket.

Receiver

 

9-Volt

Terminal

Alkaline

Battery

Wires

 

Battery Clip

Figure 37 - Attaching Alkaline Battery to Receiver

To Optional

Remote

Accessory

Figure 38 - Control Valve Terminals

9-Volt

Terminal

Wires

Battery

 

Remote

Control

Unit

Battery

Cover

Figure 40 - Installing Battery in Hand-Held Remote Control Unit (GHRCTB Series)

REMOVING/REPLACING GLASS DOOR

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part infor- mation see Replacement Parts, page 31.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before removing glass door or louvers.

Removing Louver Panels

Remove the top and bottom louver panels by simultaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from the locating holes (see Figure 41). Repeat for bottom spring latches and pull the louvers outward. To install or replace items removed, simply reverse the procedures above.

Installing 9-Volt Alkaline Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to a 9-volt alkaline battery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote control unit.

Louver Panel

Spring Latch

Battery Cover

Terminal

Wires

9-Volt Alkaline Battery

Remote Control Unit

Battery

Housing

Figure 41 - Removing Louver Panel

Figure 39 - Installing Alkaline Battery in Hand-Held Remote

Control Unit (GHRCB)

For morevisit www..com

111921-01D

Image 21
Contents OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsHigh Altitude Installation Vertical VentingNumber Description Installing Optional Blower Accessories Fireplace InstallationModel BK Installation Check GAS TypeBlower Model BKT Model BKT Installation Installing GAS Piping to Fireplace Location Blower Wiring Diagram Installation Items Needed Installation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Installing Remote Receiver REMOVING/REPLACING Glass DoorRemoving Louver Panels Installing Brick Liner Models BL42DASA and BL42DHASA Cleaning Glass DoorRemoving Glass Doors Crossover log onto logs #4 and #5 as shown in Figure Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsOptional HAND-HELD Remote Operation Thermostat Series Models GhrctbON/OFF Series Models Ghrcb Pilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementService Hints Replacement PartsTechnical Service SpecificationsModels Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListBurner Assembly for Models VK42N, VK42NH, VK42P, VK42PH Parts List Accessories Owners Registration Form For Com 111921-01D Warranty Information