Hobart Welding Products 210 Connecting To Weld Output Terminals, Installing Work Clamp Cable

Models: M-10 210

1 56
Download 56 pages 12.21 Kb
Page 16
Image 16

3-6. Connecting To Weld Output Terminals

4

 

1

 

 

 

 

 

Do not place

 

 

 

anything between

 

 

 

weld cable terminal

 

 

 

and copper bar.

 

2

 

 

Tools Needed:

3

 

 

 

 

 

3/4 in (19 mm)

 

 

 

 

 

Correct Installation

Y Turn off power before connecting to

1

Weld Output Terminal

weld output terminals.

 

2

Supplied Weld Output Terminal Nut

 

 

Y Failure to properly connect weld

3

Weld Cable Terminal

cables may cause excessive heat

4

Copper Bar

and start a fire, or damage your

Remove supplied nut from weld output ter-

machine.

 

803 778-A

Incorrect Installation

minal. Slide weld cable terminal onto weld output terminal and secure with nut so that weld cable terminal is tight against copper bar. Do not place anything between weld cable terminal and copper bar. Make

sure that the surfaces of the weld cable terminal and copper bar are clean.

3-7. Installing Work Clamp Cable

Tools Needed:

2

1

1 Work Cable

Route cable through opening in front panel.

2Negative (−/Black) Output Terminal

Connect cable to terminal. Close door.

3/4 in

Ref. 802 601-A / Ref. 801 566-B

OM-927 Page 12

Page 16
Image 16
Hobart Welding Products 210, M-10 installation instructions Connecting To Weld Output Terminals, Installing Work Clamp Cable