3-13. Selecting A Location And Connecting Input Power

Y Do not move or operate unit where it could tip.

18 in (457 mm) of space for airflow

 

1

 

8

 

=GND/PE Earth Ground

 

10

 

 

7

 

 

9

 

 

L1

4

 

L2

 

 

5

 

 

 

6

 

2

1

3

L2L1

230 VAC, 1

YInstallation must meet all Na- tional and Local Codes − have only qualified persons make this installation.

YSpecial installation may be required where gasoline or volatile liquids are present − see NEC Article 511 or CEC Section 20.

YDisconnect and lockout/tag- out input power before con- necting input conductors from unit.

YAlways connect green or green/yellow conductor to supply grounding terminal

first, and never to a line ter- minal.

1 Rating Label

Supply correct input power.

2Plug

3Receptacle

Connect plug to receptacle.

4Black And White Input Conductor (L1 And L2)

5Green Or Green/Yellow Grounding Conductor

6Input Power Cord.

7Disconnect Device (switch shown in the OFF position)

8Disconnect Device Grounding Terminal

9Disconnect Device Line Terminals

Connect green or green/yellow grounding conductor to disconnect device grounding terminal first.

Connect input conductors L1 and L2 to disconnect device line termi- nals.

10 Over-Current Protection

Select type and size of over-current protection using Section 3-12(fused disconnect switch shown).

Close and secure door on discon- nect device. Remove lockout/tag- out device, and place switch in the On position.