OM-927 Page 9
SECTION 3 INTRODUCTION

3-1. Specifications

Max. Open
Circuit
Amps Input at Rated Output, 60 Hz, Single-Phase
Rated Output Circuit
Voltage 200 V 230 V KVA KW
150 A at 23 VDC,
40% Duty Cycle 33 29
2.3* 25
2* 5.8
0.4* 4.9
0.1*
Wire Type and Diameter No Load Wire Feed
Speed Dimensions Weight
Solid Steel/
Stainless Steel Aluminum Flux Cored
90750 IPM
(2.319 m/min) H: 31-1/4 in (794
mm)
W: 18-7/8 in (479
146 lb
(66 kg)
.023 .045 in
(0.6 1.2 mm) .030 .035 in
(0.8 0.9 mm) .030 .045 in
(0.8 1.2 mm)
W: 187/8 in (479
mm)
D: 36-1/2 in (927
mm)
* While idling

3-2. Welding Power Source Duty Cycle And Overheating

Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
voltage, or duty cycle before
welding.
YExceeding duty cycle can
damage unit and void
warranty.
Overheating
0
15

A or V

OR
Reduce Duty Cycle
Minutes
duty1 4/95 199 211
4 Minutes Welding 6 Minutes Resting
40%dutycycle