Desa CGCF26TPA Operating Fireplace, For Your Safety Read Before Lighting, Lighting Instructions

Page 14

CGCF26TPA

VENT-FREE COMPACT FIREPLACE

OPERATING

FIREPLACE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

LIGHTING

INSTRUCTIONS

WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is installed before running fireplace.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Orange flame will also be present. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1.STOP! Read the safety information column 1.

2.Make sure manual shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information at the top of column 1. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

to the PILOT position. Press in control knob for five (5) seconds (see Figure 22).

Note: You may be running this fire- place for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

Control Knob

Ignitor

Button

Figure 22 - Control Knob In The OFF Position

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is at- tached to the front of burner. If needed, keep pressing ignitor but- ton until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 16 through 18. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 15.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This fireplace has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise

to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 23 - Pilot

(Actual Pilot May Vary From Illustration)

14

104278

Image 14
Contents VENT-FREE PROPANE/LP GAS Compact Fireplace What to do if YOU Smell GASSafety Information CGCF26TPA VENT-FREE Compact FireplaceUnpacking Productproduct IdentificationfeaturesLocal Codes Assembling Fireplace AssemblyInstalling Log Assembling HoodUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items Locating FireplaceBUILT-IN Fireplace Installation Rough Opening for Installing in CornerMantel Clearances for BUILT-IN Installation Optional Mantel InstallationConnecting to GAS Supply Attaching Wood Base to Solid FloorConnecting Fireplace to GAS Supply Installation Items NeededChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Inspecting Burner Troubleshooting Observed Problem Possible Cause RemedyBurner damaged Gas leak. See Warning statement at Service Hints Cleaning and MaintenanceReplacement Parts Illustrated Parts Breakdown CGCF26TPAParts List KEY CGCF26TP Description QTYBrass Trim KIT GA6095 AccessoriesCorner Mantel with BUILT-IN Hearth Base Parts Centrals SpecificationsTechnical Service FBDLimited Warranty VENT-FREE PROPANE/LP GAS Compact Fireplace International