Desa CGCF26TPA installation manual Burner damaged

Page 17

OWNER’S MANUAL

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1.

Burner orifice is clogged

 

2.

Burner orifice diameter is too small

 

3.

Inlet gas pressure is too low

1.Clean burner (see Cleaning and Mainte- nance, page 19) or replace burner orifice

2.Replace burner orifice

3.Contact local propane/LP gas company

Delayed ignition of burner

1.

Manifold pressure is too low

1.

Contact local propane/LP gas company

 

2.

Burner orifice is clogged

2.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 19) or replace burner orifice

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

2.

Burner damaged

 

nance, page 19) or replace burner orifice

 

2.

Replace burner pressure

 

3.

Low inlet gas pressure

3.

Contact local propane/LP gas company

 

4.

Gas regulator defective

4.

Replace gas regulator

Yellow flame during burner combustion

1.

Not enough air

 

2.

Gas regulator defective

1.Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance, page 19)

2.Replace gas regulator

Slight smoke or odor during initial operation

1.

Residues from manufacturing processes

1.

Problem will stop after a few hours of

 

 

 

 

operation

 

 

 

 

 

Fireplace produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

burner is lit

 

when burner is cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

line. Have gas line checked by local pro-

 

3.

Air passageways on fireplace blocked

 

pane/LP gas company

 

3.

Observe minimum installation clear-

 

4.

Dirty or partially clogged burner orifice

 

ances (see Figures 6 and 7, page 8)

 

4.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 19) or replace burner orifice

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. turn into white powder residue

1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

www.desatech.com

Continued

104278

17

Image 17
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GAS Compact FireplaceCGCF26TPA VENT-FREE Compact Fireplace Safety InformationUnpacking Productproduct IdentificationfeaturesLocal Codes Installing Log AssemblyAssembling Fireplace Assembling HoodProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Items InstallationCheck GAS Type Locating FireplaceRough Opening for Installing in Corner BUILT-IN Fireplace InstallationOptional Mantel Installation Mantel Clearances for BUILT-IN InstallationAttaching Wood Base to Solid Floor Connecting to GAS SupplyInstallation Items Needed Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Lighting Instructions For Your Safety Read Before LightingOperating Fireplace Inspecting Burner Observed Problem Possible Cause Remedy TroubleshootingBurner damaged Gas leak. See Warning statement at Service Hints Cleaning and MaintenanceReplacement Parts CGCF26TPA Illustrated Parts BreakdownKEY CGCF26TP Description QTY Parts ListBrass Trim KIT GA6095 AccessoriesCorner Mantel with BUILT-IN Hearth Base Technical Service SpecificationsParts Centrals FBDInternational Limited Warranty VENT-FREE PROPANE/LP GAS Compact Fireplace