Fireplace

SAFETY PILOT

This fireplace has a pilot with an Oxygen

Cabinet

 

Depletion Sensor Shutoff System (ODS).

 

The ODS/pilot is a required feature for vent-

 

free room fireplaces. The ODS/pilot shuts off

 

the fireplace if there is not enough fresh air.

Screen

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This sys- tem requires no matches, batteries, or other sources to light fireplace.

Logs

Control Knob

THERMOSTATIC HEAT CONTROL

This fireplace has a thermostat sensing bulb and a control valve. The thermostat will automatically modulate the heat output to maintain a consistent room temperature. This results in greater fireplace comfort. This can also result in lower gas bills.

Ignitor Button

Figure 1 - Vent-Free Gas Compact Fireplace

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

UNPACKING

1.Remove log box and fireplace from carton. The hood is not attached.

2.Remove all protective packaging ap- plied to fireplace for shipment.

3.Make sure your fireplace includes one hardware packet.

4.Check fireplace for any shipping damage. If fireplace is damaged, promptly inform dealer where you bought fireplace.

104278

3

Image 3
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GAS Compact FireplaceCGCF26TPA VENT-FREE Compact Fireplace Safety InformationProductproduct Identificationfeatures Local CodesUnpacking Assembling Hood AssemblyInstalling Log Assembling FireplaceConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Locating Fireplace InstallationInstallation Items Check GAS TypeRough Opening for Installing in Corner BUILT-IN Fireplace InstallationOptional Mantel Installation Mantel Clearances for BUILT-IN InstallationAttaching Wood Base to Solid Floor Connecting to GAS SupplyInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections For Your Safety Read Before Lighting Operating FireplaceLighting Instructions Inspecting Burner Observed Problem Possible Cause Remedy TroubleshootingBurner damaged Gas leak. See Warning statement at Cleaning and Maintenance Replacement PartsService Hints CGCF26TPA Illustrated Parts BreakdownKEY CGCF26TP Description QTY Parts ListAccessories Corner Mantel with BUILT-IN Hearth BaseBrass Trim KIT GA6095 FBD SpecificationsTechnical Service Parts CentralsInternational Limited Warranty VENT-FREE PROPANE/LP GAS Compact Fireplace