Desa CGCF26TPA installation manual Troubleshooting, Observed Problem Possible Cause Remedy

Page 16

CGCF26TPA

VENT-FREE COMPACT FIREPLACE

TROUBLESHOOTING

Note: For additional help, visit DESA International’s Technical Service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off and un- plug fireplace and let cool before servicing. Only a qualified ser- vice person should service and repair fireplace.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no

1.

Ignitor cable pinched or wet

1.

Free ignitor cable if pinched by any

spark at ODS/pilot

 

 

 

metal or tubing. Keep ignitor cable dry

 

2.

Ignitor electrode not connected to igni-

2.

Reconnect ignitor cable

 

 

tor cable

 

 

 

3.

Broken ignitor cable

3.

Replace ignitor cable

 

4.

Bad piezo ignitor

4.

Replace piezo ignitor

 

5.

Ignitor electrode broken

5.

Replace ignitor

 

6.

Ignitor electrode positioned wrong

6.

Replace ignitor

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or manual shutoff

1.

Turn on gas supply or open manual

spark at ODS/pilot but no ignition

 

valve closed

 

shutoff valve

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

PILOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

Repeat igniting operation until air is

 

 

 

 

removed

 

5.

Depleted gas supply

5.

Contact local propane/LP gas company

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 19) or replace ODS/

 

 

 

 

pilot assembly

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

knob pressed in 30 seconds

 

3.

Safety interlock system has been triggered

3.

Wait one minute for safety interlock sys-

 

 

 

 

tem to reset. Repeat ignition operation

 

4.

Manual shutoff valve not fully open

4.

Fully open manual shutoff valve

 

5.

Thermocouple connection loose at con-

5.

Hand tighten until snug, then tighten 1/4

 

 

trol valve

 

turn more

 

6.

Pilot flame not touching thermocouple,

6.

A) Contact local propane/LP gas company

 

 

which allows thermocouple to cool,

 

 

 

 

causing pilot flame to go out. This prob-

 

B) Clean ODS/pilot (see Cleaning and

 

 

lem could be caused by one or both of

 

Maintenance, page 19) or replace ODS/

 

 

the following:

 

pilot assembly

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

7.

Thermocouple damaged

7.

Replace thermocouple

 

8.

Control valve damaged

8.

Replace control valve

www.desatech.com

16

104278

Image 16
Contents VENT-FREE PROPANE/LP GAS Compact Fireplace What to do if YOU Smell GASSafety Information CGCF26TPA VENT-FREE Compact FireplaceLocal Codes Productproduct IdentificationfeaturesUnpacking Assembly Installing LogAssembling Fireplace Assembling HoodAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Installation ItemsCheck GAS Type Locating FireplaceBUILT-IN Fireplace Installation Rough Opening for Installing in CornerMantel Clearances for BUILT-IN Installation Optional Mantel InstallationConnecting to GAS Supply Attaching Wood Base to Solid FloorConnecting Fireplace to GAS Supply Installation Items Needed Pressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping System Checking GAS Connections Operating Fireplace For Your Safety Read Before LightingLighting Instructions Inspecting Burner Troubleshooting Observed Problem Possible Cause RemedyBurner damaged Gas leak. See Warning statement at Replacement Parts Cleaning and MaintenanceService Hints Illustrated Parts Breakdown CGCF26TPAParts List KEY CGCF26TP Description QTYCorner Mantel with BUILT-IN Hearth Base AccessoriesBrass Trim KIT GA6095 Specifications Technical ServiceParts Centrals FBDLimited Warranty VENT-FREE PROPANE/LP GAS Compact Fireplace International