Desa (V)VC36NE Series, (V)VC36PE Series REMOVING/REPLACING Glass Door, Removing Louver Panels

Page 20

20

FIREPLACE INSTALLATION

Checking Gas Connections (Cont.)

Removing/Replacing Glass Door

FIREPLACE INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 33).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air.

3.Check all joints from propane/LP supply tank or gas meter to equip- ment shutoff valve (see Figure 34 for propane/LP or Figure 35 for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Equipment

Open

Shutoff

 

 

Valve

 

 

 

 

Closed

Figure 33 - Equipment Shutoff Valve

 

 

Equipment

 

Propane/LP

Shutoff

 

Valve

 

Supply Tank

 

 

 

 

Gas Valve

 

Figure 34 - Checking Gas Joints for Propane/LP Gas Fireplace

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Figure 33).

2.Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to gas valve (see Figure 34 for propane/LP or Figure 35 for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light fireplace (see Operating Fireplace, page 23). Check all other internal joints for leaks.

6.Turn off fireplace (see To Turn Off Gas to Appliance, page 24).

REMOVING/REPLACING GLASS DOOR

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part infor- mation see Replacement Parts, page 28.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before removing glass door or louvers.

Removing Louver Panels

Remove the top and bottom louver panels by simultaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from the locating holes (see Figure 36). Repeat for bottom spring latches and pull the louvers outward. To install or replace items removed, simply reverse the procedures above.

Equipment

Shutoff

Valve

Gas

Meter

Gas Valve Figure 35 - Checking Gas Joints for Natural Gas Fireplace

Spring Latch

Louver Panel

Figure 36 - Removing Louver Panel

www.desatech.com

116235-01B

Image 20
Contents For Your Safety For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Product Identification Local CodesControl Valve BlowerLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Clearances Framing and Finishing35 3/4 133/4 10 3/8 49 5/8 681/2Location of Termination CAP Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationMale Female Slots Locking Lugs CenterVent Cap Wood Screw Interior Wall Surface Firestop Vent CapHorizontal Vent PipeHorizontal Termination Configurations Snorkel Termination Minimum Vertical30 max Venting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationRoof Flashing Wall Strap Elbow Ceiling Firestop If area above is a room orVertical Termination Configurations Elbow Into inner collar fireplace as shownHigh Altitude Installation Venting Installation Fireplace Installation Check GAS TypeInstalling Optional Blower Accessory Desa 5/8 Pipe & Vent KitsFireplace Installation Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Removing Louver Panels Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Removing Glass Door Installing Lava Rock and Glowing EmbersCleaning Glass Door Optional Remote Control Installing Brick Liner Models BL36DASA and BL36DHASAWall Switch Installation Wiring Diagram For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsOperating Optional Blower Accessory To Turn OFF GAS To ApplianceOptional Remote OperationCleaning Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning statement at Replacement Parts Service HintsTechnical Service Parts Under WarrantySpecifications Illustrated Parts Breakdown Models VC36NE, VVC36NE, VC36PE and VVC36PEParts List KEY Part Number Description QTY2827 19 18 KEY Part Number Description Accessories Date Purchased Serial Number BrandModel Industrial Drive Box Bowling Green, KY 116235-01B Industrial Drive P.O. Box Warranty InformationModel Serial No Date Purchased