Desa (V)VC36NE Series, (V)VC36PE Series Installing Brick Liner Models BL36DASA and BL36DHASA

Page 22

22

FIREPLACE INSTALLATION

Installing Optional Brick Liner Models BL36DA(SA) and BL36DHA(SA)

Wall Switch Installation

Optional Remote Control Installation

FIREPLACE INSTALLATION

Continued

INSTALLING BRICK LINER MODELS BL36DA(SA) AND BL36DHA(SA)

WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before installing brick liner.

You may purchase brick liner from your local retailer or see Ac- cessories, page 34.

CAUTION: Always handle brick panels with two hands. Do not force brick panels into place. Exces- sive force will break brick panels.

1.Remove top and bottom louvers to allow access to door latches.

2.Unlock door latches and open glass door. See Removing Glass Door, steps 1 and 2, page 21.

3.Carefully remove lava rock and ember material. Remove log/ grate assembly by unscrewing grate from plenum. The two logs under the grate are attached to burner. DO NOT attempt to remove.

4.Remove screws that attach plenum to burner to remove plenum.

5.Remove three screws from deflector shield on the inside top of firebox. Set shield and screws aside.

6.Install rear brick panel first. Rest bottom edge of panel on back edge of burner assembly (see Figure 39).

7.Install left side brick panel by sliding it between the burner assembly and the side of the firebox (see Figure 39).

8.Install the right brick panel using the same method described in step 6 for left brick panel.

9.Replace deflector shield using screws removed in step 4.

10.Using scews removed in step 4, replace plenum and attach to burner.

11.Using screws removed in step 3, replace log/grate assembly. Be care- ful when replacing log/grate assembly not to chip logs on burner.

12.Install lava rock and glowing embers. See Installing Lava Rock and Glowing Embers, page 21.

13.Close glass door and lock latches on top and bottom of door and replace screen. See Removing Glass Door, steps 5 and 6, page 21.

14.Close top and bottom louvers.

WALL SWITCH INSTALLATION

The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies the electricity to the fireplace.

OPTIONAL REMOTE CONTROL

INSTALLATION (Model WRC)

Note: If using optional wireless hand-held remote control, the wall switchmustbeintheONpositiontobeoperational.Theremotecontrol then becomes the switching mechanism for fireplace operation.

1.Open lower louver panel.

2.The WRC model receiver does not require a battery. The receiver can be installed by first plugging the short extension cord into the fireplace receptacle. Then plug the receiver unit into the extension cord. Finally plug the ignition module plug into the receiver unit (see Figure 40).

3.Activate the remote handset battery by removing the insulating tab on the back of the handset (see Figure 41). The battery is included pre-installed.

4.Once the battery is activated the unit is ready to use.

5.Close lower louver panel.

Fireplace

Remote Control

Receptacle

 

Receiver

Left Side

Brick Panel

Rear Brick

Panel

Figure 39 - Installing Rear Brick Panel

Extension Cord

 

Ignition

 

 

 

 

Module Plug

Figure 40 - Installing the WRC Remote Receiver

 

Battery Cover

 

 

12 Volt Battery

 

 

Back of

Pull to Remove

 

Handset

 

Insulation Tab

 

 

Figure 41 - Installing Battery into Back of Handset

www.desatech.com

116235-01B

Image 22
Contents For Your Safety For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationControl Valve Safety Information Product IdentificationLocal Codes BlowerPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements 35 3/4 133/4 10 3/8 49 5/8 ClearancesFraming and Finishing 681/2Location of Termination CAP Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsMale Female Slots Locking Lugs Installation PlanningHorizontal Termination Installation CenterHorizontal Vent Cap Wood ScrewInterior Wall Surface Firestop Vent Cap Vent PipeHorizontal Termination Configurations 30 max VerticalSnorkel Termination Minimum Venting with Two 90 Elbows Roof Flashing Wall Strap Elbow Ceiling Firestop Installation for Vertical TerminationFlat Ceiling Installation If area above is a room orVertical Termination Configurations Elbow Into inner collar fireplace as shownHigh Altitude Installation Installing Optional Blower Accessory Venting InstallationFireplace Installation Check GAS Type Desa 5/8 Pipe & Vent KitsFireplace Installation Model BKT InstallationBlower Wiring Diagram Installing GAS Piping to Fireplace LocationInstallation Items Needed Pressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyChecking GAS Connections REMOVING/REPLACING Glass Door Pressure Testing Fireplace Gas ConnectionsRemoving Louver Panels Cleaning Glass Door Installing Lava Rock and Glowing EmbersRemoving Glass Door Wall Switch Installation Installing Brick Liner Models BL36DASA and BL36DHASAOptional Remote Control Operating Fireplace Wiring DiagramFor Your Safety Read Before Lighting Lighting InstructionsOptional Remote Operating Optional Blower AccessoryTo Turn OFF GAS To Appliance OperationPilot and Burners Cleaning MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning statement at Technical Service Replacement PartsService Hints Parts Under WarrantySpecifications Illustrated Parts Breakdown Models VC36NE, VVC36NE, VC36PE and VVC36PEParts List KEY Part Number Description QTY2827 19 18 KEY Part Number Description Accessories Model BrandDate Purchased Serial Number Industrial Drive Box Bowling Green, KY 116235-01B Model Serial No Date Purchased Warranty InformationIndustrial Drive P.O. Box