Desa CGCF26TNA installation manual Assembly, Assembling Fireplace, Installing Log, Assembling Hood

Page 4

VENT-FREE NATURAL GAS COMPACT FIREPLACE

ASSEMBLY

WARNING: Always have branch support and screen in place before operating fireplace. This prevents excessive tempera- tures on fireplace surfaces.

ASSEMBLING FIREPLACE

Tools Required:

Phillips screwdriver

5/16" hex wrench

slotted screwdriver

Installing Log

1.

Remove back log, branch, and hood from

 

log box. Discard protective packaging.

2.

Remove two shipping screws above

 

screen (see Figure 2).

3.

Lift screen up and pull out to remove.

4.

An optional blower is available. See Ac-

 

cessories, page 22. Install optional

 

blower now. Follow installation in-

 

structions provided with blower.

5.

Gently place back log on burner sup-

 

port (see Figure 2). The log should fit

 

Screen

Back Log

Shipping

Screw

 

Shoulder Screw

Burner

Support

Screw

Branch

Branch

Support

Screw

Screen

Figure 2 - Assembling Fireplace

flat against top of burner support. Place

two #10 one-inch-long screws through

burner support into the log and tighten.

Place branches on branch support (see

Figure 2).

6. Reattach screen by placing notches in

screen frame over shoulder screws and

pushing down.

Assembling Hood

1.Locate four #10-3/8" black phillips sheet metal screws from the hardware packet.

2.Remove two 13/4" screws from under- neath middle rail (see Figure 3).

3.Slip top of hood between middle rail and top of firebox wrapper (see Figure 3).

4.Reinstall two 13/4" screws removed in step 2. Make sure screw pass through hood and middle rail and attach into upper louver assembly (see Figure 3).

5.Attach four #10-3/8" hood screws as shown in Figure 3.

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in prop- erty damage or personal injury.

Middle Rail

Firebox

Wrapper

Hood

#10-3/8" Screws

Figure 3 - Assembling Hood

4

104277

Image 4
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information VENT-FREE Natural GAS Compact FireplaceProduct Features Product IdentificationLocal Codes UnpackingAssembly Installing LogAssembling Fireplace Assembling HoodAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Installation ItemsCheck GAS Type Locating FireplaceBUILT-IN Fireplace Installation Rough Opening for Installing in CornerMantel Clearances for BUILT-IN Installation Optional Mantel InstallationConnecting to GAS Supply Attaching Wood Base to Solid FloorConnecting Fireplace to GAS Supply Installation Items NeededPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Operating Fireplace For Your Safety Read Before LightingLighting Instructions Inspecting Burner Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Replacement Parts Cleaning and MaintenanceService Hints Illustrated Parts Breakdown CGCF26TNAParts List KEY Description QTYAccessories Manual Shutoff Valve GA5010Brass Trim KIT GA6095 Thermostatically Controlled Blower KIT GA3450TSpecifications Technical ServiceParts Centrals FBDWarranty Information Limited Warranty VENT-FREE Natural GAS Compact Fireplace