Kobe Range Hoods CH7942SQB, CH7936SQB, CH7948SQB Under The Cabinet Installation - Top Vent

Models: CH7930SQB CH7948SQB CH7942SQB CH7936SQB

1 102
Download 102 pages 18.25 Kb
Page 9
Image 9

UNDER THE CABINET INSTALLATION – TOP VENT

Preparation before Installation

NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING.

-Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1.

-A straight, short venting run will allow the hood to perform more efficiently.

-Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood.

-Temporarily wire the hood to test for proper operation before installing.

-Peel protective film off the hood (if any).

-For installing under the cabinet with recessed bottom, attach 4-inch wide wood filler strips (not included) on each side. Refer to Figure 2.

-Measure and create access opening for electrical wires under the cabinet.

-Cut the multi duct exhaust according to the size of the venting pipe. Refer to Figure 3.

Figure 1

Figure 2

6" Round Vent

7" Round Vent

3-1/4" x 10" Vent

 

 

 

 

 

Figure 3