CHDV37N/P(A,B) AND CHDV41N/P(A,B)
DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)
VENTING INSTALLATION
Continued
Horizontal Termination
Configurations
Figures 16 through 20 show different con- figurations for venting with horizontal ter- mination. Each figure includes a chart with vertical minimum/maximum and horizon- tal maximum dimensions which must be met. Seal all connections with high tem- perature silicone sealant (outer pipe only) as specified in the second warning statement on page 7. All horizontal terminations re- quire 1/4" rise per 12" of horizontal run.
UP
CBGFVK Vent Kit Shown (recommended for use with cabinet mantel)
Horizontal Venting
Vertical (V) | Horizontal (H) |
37" min. | 10" max. |
Figure 16 - Horizontal Termination Configuration for Rigid Venting
UP
Horizontal Venting
Vertical (V) | Horizontal (H) |
44" min. | 29" max. |
(30° and 90° only, no vertical pipe)
55" min. | 41" max. |
(30° elbow, 1' vertical pipe, 90° elbow)
67" min. | 60" max. |
79" min. | 84" max. |
96" min. | 20' max. |
Note: This configuration for use with corner installation.
CBVK Vent Kit Shown
Figure 17 - Horizontal Termination Configuration for Rigid Venting Using One 90° Elbow
Horizontal Venting
See information in |
|
Figure 17 for |
|
Vertical(V) and |
|
Horizontal(H) maxi- | UP |
mums and mini- |
|
| |
mums. The same |
|
amounts apply for |
|
flexible venting. (A |
|
higher termination |
|
mounting location is |
|
desirable.) |
|
Note: Figure 16 |
|
applies to rigid |
|
venting only. |
|
Figure 18 - Horizontal Termination Using Flexible Venting
10 | 105542 |