Desa CHDV41N/P, CHDV37N/P Wireless HAND-HELD Remote Control, REMOVING/REPLACING Glass Door

Page 21

OWNER’S MANUAL

FIREPLACE INSTALLATION

Continued

WIRELESS HAND-HELD REMOTE CONTROL

(Included)

Installing Battery into Receiver

1.Open bottom louver and locate the switch bracket on the left.

2.Unscrew the switch bracket. Lean bracket forward so you are able to ac- cess the back of the remote receiver.

3.Locate the battery clip mounted on the back of the receiver. Slide a 9-volt bat- tery (not included) through the clip.

4.Attach the terminal wires to the battery.

5.Replace the switch bracket.

Receiver

Terminal

Wires

Battery Clip

9-Volt Battery

Figure 40- Attaching Battery to Receiver

Installing 9-Volt Battery in Hand- Held Remote Control Unit

REMOVING/REPLACING GLASS DOOR

You must remove glass door to install op- tional brick liners, logs, lava rock, and em- ber material.

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For re- placement part information see Replacement Parts, page 31.

Top Louver

Panel

Figure 42 - Removing Top Louver Panel

1.Remove the upper louver panel by lift- ing upward and out (see Figure 42).

2.Remove the screws from the three tabs at the top of the glass door while hold- ing door securely keeping it from fall- ing forward.

3.Grasp door by both sides and ease it upward off of the lower bracket (see Figure 43).

4.To replace glass door, follow the above instructions in reverse.

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to a 9-volt bat- tery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote con-

trol unit.

 

Battery

 

Terminal

Cover

Remote

 

Wires

 

Control Unit

9-Volt

 

 

Battery

 

 

 

 

Battery

 

 

Housing

Figure 41 - Installing Battery in Hand- Held Remote Control Unit

Screw

Glass

Door

Assembly

Lower Bracket for

Glass Door Assembly

Figure 43 - Removing/Replacing Glass Door

Continued

105542

21

Image 21
Contents For Your Safety For Your Safety What to do if YOU Smell GASCHDV37N/PA,B and CHDV41N/PA,B DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Termination Configuration for Rigid Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Parts Lists for Venting Kits and Components High Altitude InstallationComfort Glow Rigid Venting Comfort Glow Flexible VentingInstalling Optional Blower Accessory Fireplace InstallationInstalling GA3750/CDA3620T Blowers Check GAS TypeIf your fireplace system is installed Installation Items Needed Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsClose manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsIncluded Installing Battery into Receiver Wireless HAND-HELD Remote ControlInstalling 9-Volt Battery in Hand- Held Remote Control Unit REMOVING/REPLACING Glass DoorAttaching Magnetic Decorative Brass Strips Installing Optional Brick Liner CD8037A/ CD8041Fireplace Models CHDV37N/P and CHDV41N/P Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsHAND-HELD Remote Operation Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersBurner Flame Pattern Glass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsService Hints Technical ServiceCHDV37NA,B CHDV37PA,B CHDV41NA,B CHDV41PA,B SpecificationsManual Blower KIT GA3750 AccessoriesTHERMOSTATICALLY- Controlled Blower KIT CDA3620T GMC41F41 Walnut Stained Hardwood VeneerCHDV37NA,B CHDV41NA,B Illustrated Parts BreakdownDIRECT-VENT Fireplace CHDV37NA,B CHDV41NA,B Parts ListCHDV37PA,B CHDV41PA,B DIRECT-VENT Fireplace CHDV37PA,B CHDV41PA,B Warranty Information