Desa DVF34P PRE-INSTALLATION General Venting Preparation, Location of Vent, Termination

Page 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OWNER’S MANUAL

 

PRE-INSTALLATION

 

 

 

 

 

 

 

 

 

 

GENERAL VENTING

PREPARATION

 

 

 

 

 

 

 

 

 

 

These models are approved for use with

Continued

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FMI 7" direct-vent pipe components and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

terminations.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Your fireplace is approved to be vented either

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

through the side wall, or vertically using the

13"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

following guidelines:

9 1/4"

 

41"

 

 

 

 

 

 

• Only use FMI venting components or kits

29"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

specifically approved for this fireplace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Minimum clearance between vent pipes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and combustible materials is 1" (25 mm),

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

except where stated otherwise.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Combustible material may be flush with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the top front of fireplace with a maxi-

 

12 5/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mum thickness of 3/4".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Do not recess venting terminals into a

 

 

 

34 3/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

wall or siding.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35

1

/16"

 

 

 

 

 

 

 

Nailing Tabs

• If exterior wall is vinyl, you must use a

 

 

 

 

 

 

 

 

 

 

 

vinyl siding standoff.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58"

 

 

 

 

 

 

 

 

 

 

 

• Install horizontal venting with a 1/4" rise

 

 

 

 

 

 

 

 

 

 

 

 

 

for every 12" of run toward the termination.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 6 - Framing Clearances for Corner Installation

 

• You may paint the vent terminal with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

450ºF (232ºC) heat-resistant paint to co-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ordinate with the exterior finish.

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

• There must not be any obstruction such

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

as bushes, garden sheds, fences, decks,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

or utility buildings within 24" from the

Note: There must be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

front of the termination cap.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a minimum clear-

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

• Do not locate termination cap where exces-

ance of 18" above

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall

 

sive snow or ice build up may occur. Be sure

top of louver

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to clear vent termination area after snow falls

opening when

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to prevent accidental blockage of venting

installing a television

 

 

 

B

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

system. When using snow blowers, do not

or entertainment

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

center above the

 

 

 

 

 

6

 

 

 

 

 

 

 

 

direct snow towards vent termination area.

fireplace.

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

LOCATION OF VENT

 

 

 

 

 

 

 

 

 

G

 

 

 

TERMINATION

 

 

 

Top of Louver Opening

Ref.

Mantel Depth

Ref.

Mantel from Top

 

 

 

 

of Louver Opening

 

 

 

 

 

 

1

14" (356mm)

A

16" (406mm)

 

 

 

 

 

 

2

12" (305mm)

B

14" (356mm)

 

3

10" (254mm)

C

12" (305mm)

 

 

 

 

 

 

4

8" (203mm)

D

10" (254mm)

 

 

 

 

 

 

5

6" (152mm)

E

8" (203mm)

 

 

 

 

 

 

6

4" (101mm)

F

6" (152mm)

 

 

 

 

 

 

7

2" (51mm)

G

4" (101mm)

 

 

 

 

 

 

When locating vent termination, it is impor- tant to observe the minimum clearances shown in Figure 8, page 6. You will avoid extra framing by positioning your fireplace against an already existing framing mem- ber. The sides of the fireplace may be posi- tioned directly against combustible walls.

*Check with local codes or with the current CAN/CGA B149 [.1 or .2] Installation Codes for Canada or the USA Installations follow the current National Fuel Gas Code, ANS Z223.1, also known as NFPA 54.

Figure 7 - Clearances for Combustible Mantels

Continued

106424

5

Image 5
Contents Natural GAS Model DVF34 PROPANE/LP GAS Model DVF34P For Your SafetyFor Your Safety What to do if YOU Smell GAS DVF34, DVF34P DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationLocal Codes Product IdentificationGlossary Terms OperationClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingTermination PRE-INSTALLATION General Venting PreparationLocation of Vent General Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination with Drainage Pipe Installation for Horizontal TerminationRigid Vent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Venting with Two 90 Elbow s Vertical Termination ConfigurationsVertical Venting FMI Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Installing Optional Blower Accessory Fireplace InstallationInstalling GA3700/DA3610TA Blowers Check GAS TypeIf your fireplace system is installed Installation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Close equipment shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Installing Optional Wall Mount Switch GWMS2Installing 9-Volt Alkaline Battery into Receiver Attaching Magnetic Decorative Brass Strips Installing Optional Brick Liner D8037AInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsOperating Optional GWMS2 Wall Mounted Switch Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersCleaning and Maintenance Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsService Hints Technical ServiceDVF34 DVF34P SpecificationsDVF34 DVF34P Illustrated Parts BreakdownDIRECT-VENT Fireplace DVF34 DVF34P Parts ListAccessories 106424 Warranty Information