Desa DVF34P Vertical Termination Configurations, Venting with Two 90 Elbow s

Page 13

OWNER’S MANUAL

VENTING INSTALLATION

Continued

3.Lower the support box through the hole in the roof until the bottom of the box extends at least 2" below the ceiling (see Figure 22). Align the support box vertically and horizontally using a level. Temporarily tack the support box in place through the inside walls and into the roof sheathing.

4.Using tin snips, cut the support box from the top corners down to the roofline and fold the resulting flaps over the roof sheathing (see Figure 23). Apply a bead of non-hardening mastic around the top edges of the support box to make a seal between the box and the roof. Nail in place with roofing nails. Remove any combustible material that might be in- side of the support box.

5.Complete the cathedral ceiling instal- lation by following the same proce- dures outlined in steps 2 through 7 for Flat Ceiling Installation, page 12.

Level

Cathedral ceiling support box

2" minimum below finished ceiling

Vertical Termination Configurations

Figures 24 through 27 show four different configurations for vertical termination. All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 7.

 

Venting with Two 90° Elbows

 

Vertical (V)

Horizontal (H1) +

 

 

Horizontal (H2)

 

5' min.

2' max.

 

6' min.

4' max.

FD60

7' min.

6' max.

8' min.

8' max.

60˚ Starter/

 

 

Adapter Required

20' max.

8' max.

Note: Restrictor must be installed in all vertical installations.

Figure 24 - Vertical Rigid Venting Configuration Using Two 90° Elbows with Two

Horizontal Runs

Cut hole 1/8" larger than support box when projected onto roofline

Figure 22 - Cathedral Ceiling Support Box Installation

Non-hardening Mastic under all edges of support box before nailing

FD60

60˚ Starter/

Adapter

Required

Note: Restrictor must be installed in all vertical installations.

Venting with One 90° Elbow

Vertical (V)

Horizontal (H)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

Figure 23 - Installed Cathedral Ceiling Support Box

Figure 25 - Vertical Rigid Venting Configuration Using One 90° Elbow

Continued

106424

13

Image 13
Contents For Your Safety What to do if YOU Smell GAS For Your SafetyNatural GAS Model DVF34 PROPANE/LP GAS Model DVF34P DVF34, DVF34P DIRECT-VENT Fireplace NATURAL/PROPANE/LP Safety InformationLocal Codes Product IdentificationGlossary Terms OperationClearances PRE-INSTALLATION PreparationLocation and Space Requirements Framing and FinishingLocation of Vent PRE-INSTALLATION General Venting PreparationTermination General Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination with Drainage Pipe Installation for Horizontal TerminationRigid Vent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Venting with Two 90 Elbow s Vertical Termination ConfigurationsVertical Venting Parts Lists for Venting Kits and Components High Altitude InstallationFMI Rigid Venting Installing Optional Blower Accessory Fireplace InstallationInstalling GA3700/DA3610TA Blowers Check GAS TypeIf your fireplace system is installed Installation Items Needed Installing GAS Piping to Fireplace LocationPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyChecking GAS Connections Close equipment shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsInstalling 9-Volt Alkaline Battery into Receiver Installing Optional Wall Mount Switch GWMS2REMOVING/REPLACING Glass Door Attaching Magnetic Decorative Brass Strips Installing Optional Brick Liner D8037AInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsOperating Optional GWMS2 Wall Mounted Switch Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersCleaning and Maintenance Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsService Hints Technical ServiceDVF34 DVF34P SpecificationsDVF34 DVF34P Illustrated Parts BreakdownDIRECT-VENT Fireplace DVF34 DVF34P Parts ListAccessories 106424 Warranty Information