OWNER’S MANUAL
OPERATING
FIREPLACE
Continued
OPERATING
OPTIONAL HAND-
HELD REMOTE
NOTICE: You must light the pilot before using the
1.After lighting, let pilot flame burn for about one minute. Turn gas control knob on the control valve to ON posi- tion. Turn variable control knob any- where between HI and LO. Slide the selector switch to the REMOTE po- sition. Note: The burners may light if
IMPORTANT: Do not leave the se- lector switch in the REMOTE posi- tion when the pilot is not lit. This will drain the battery.
IMPORTANT: Be sure to press the ON/OFF buttons on the
2.Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit. IMPORTANT: To turn the pilot off, manually turn the gas control knob on the heater to the OFF position.
OPERATING
OPTIONAL BLOWER
ACCESSORY
Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.
Both the GA3700 manual blower and the DA3610TA
Note for DA3610TA Only: If you are using DA3610TA blower, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.
OPERATING
OPTIONAL GWMS2
WALL MOUNTED
SWITCH
Make sure the heater switch is on AUTO. This wall switch works just like the con- ventional light switch. Flip the switch up for on and down for off.
INSPECTING
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary.
The height of the thermopile must be 3/8" to 1/2" above the pilot flame as shown in Figure
53.The thermocouple must be at a height of about 1/8" above the pilot flame. The flame from the pilot burner must extend beyond both the thermocouple and thermopile.
If your pilot assembly does not meet these requirements:
•turn fireplace off (seeTo Turn Off Gas to Appliance, page 24)
•seeTroubleshooting, pages 27 through 29
Thermopile
3/8" to 1/2"
Pilot Burner
1/8"
Thermocouple
Piezo
Ignitor
Figure 53 - Pilot Assembly
Blower Control Knob (Optional Accessory)
OFF
ON
REMOTE
OFF
ON
Selector Switch in Remote Position
Variable Control Knob
N |
| L |
|
O |
| O | I |
T | F | O | H |
O |
|
| |
F |
|
| |
LIP |
|
|
|
|
|
|
|
Gas Control
Knob in On
Position
Note: Make sure that this switch is not in a position to be mistaken for a light switch. This may result in the heater being inad- vertently turned on without the proper precautions being taken. See installation instructions on page 21 of this manual.
Figure 52 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation
Continued
106424 | 25 |