Desa VDCFRPA, VDCFTPA Operating Fireplace, Installing LOG SET and Screen, Lighting Instructions

Page 21

INSTALLATION

Continued

IMPORTANT: The wire may be shortened but must not be lengthened.

4.Connect one bare wire end to each of the terminals of the provided wall switch.

5.Install the wall switch and cover in the wall.

INSTALLING LOG SET AND SCREEN

1.Remove log packaging material and discard packaging. Gently place log over burner (see Figure 34). Do not allow log to contact flame. If flame contacts log, soot will be created.

2.Reattach screen by placing the notches in the screen frame over the shoulder screws and pushing down.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not

use any phone in your building.

• Immediately call your gas supplier from

a neighborʼs phone. Follow the gas

supplierʼs instructions.

• If you cannot reach your gas supplier, call

the fire department.

C. Use only your hand to push in or turn the

gas control knob. Never use tools. If the

knob will not push in or turn by hand, donʼt

try to repair it, call a qualified service tech-

nician or gas supplier. Force or attempted

repair may result in a fire or explosion.

D. Do not use this appliance if any part has been

under water. Immediately call a qualified

service technician to inspect the appliance and

to replace any part of the control system and

Log

Shoulder

Screw

Screen

any gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING:You must operate this fireplace with the screen in place. Make sure fireplace screen is installed before run- ning fireplace.

Figure 34 - Installing Log and Screen

OPERATING FIREPLACE

THERMOSTAT-CONTROLLED MODELS

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

NOTICE: During initial opera- tion of new fireplace, burning logs will give off a paper-burn- ing smell. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1.STOP! Read the safety information starting in column 1.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information in column 1. If you donʼt smell gas, go to the next step.

5.Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 35, page 22).

113133-01B

www.desatech.com

21

Image 21
Contents What to do if YOU Smell GAS Shown with Optional Cabinet Mantel/Hearth Base AccessoryTable of Contents Safety Information Safety Information Product Identification Product FeaturesLocal Codes UnpackingSheet Metal Screws Hood Louver Firebox Top Hood AssemblyTools Required Phillips screwdriver Shoulder Screw ScreenAIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationFireplace Clearances Installation ItemsMinimum Clearance to Combustible Materials TopActual Framing Height BUILT-IN Fireplace InstallationFront Width DepthMantel Shelf Optional Mantel InstallationSide of Firebox Top Louver Bottom LouverInstalling Optional Blower Accessory GA3450TA Switch Power Cord Installing Blower AccessoryPlate Remote Wire Blower Harness Bracket Lower Louver Door SwitchFor Built-In Installation Extension CordBlower Bracket Connecting to GAS Supply Connecting Equipment Shutoff Valve to Heater Control Installation Items NeededChecking GAS Connections Equipment Shutoff Valve Propane/LP Supply Tank Pressure Testing Fireplace Gas ConnectionsEquipment Open Shutoff Valve Closed Gas Regulator or Gas Control Valve EquipmentInstalling Receiver Optional Wireless HAND-HELD Remote Control AccessoriesInstalling 9-Volt Battery in Hand-Held Remote Control Unit Volt Terminal Battery Wires Battery ClipFeed wires through rectangular slots Control Valve To Wall Thermostat or Switch Or SwitchRemove jumper wire from control valve see , Terminal W Terminal R RFor Your Safety Read Before Lighting Installing LOG SET and ScreenOperating Fireplace Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Shutting Off FireplaceREMOTE-READY Models For Your Safety Read Before Lighting AUTO/OFF/ON SwitchOperating Blower Piezo Flame Control Ignitor Adjustment Knob Button Pilot Ignitor Burner ElectrodePilot Burner Ignitor Electrode Auto Thermostatic Mode Manual ModeOptional HAND-HELD Remote Operation ON/OFF Series Model CghrcbSafety Features Optional GWMS2 Wall Mounted SwitchAuto Shutoff Feature Key Pad Lock FeatureInspecting Burners Cleaning MaintenanceCabinet LOG SETAir Passageways ExteriorObserved Problem Possible Cause Remedy TroubleshootingBurner orifice is clogged Burner orifice is clogged Clean burner see CleaningMote-Ready Models Only Models OnlyMote-Ready Models Only Power is low When heated, vapors fromSlight smoke or odor during Nance,Gas leak. See Warning Specifications Thermostat ModelsRemote-Ready Models Firebox Models VDC Illustrated Parts BreakdownNot a field replacement part Parts ListThermostat Models Vdcftpa and Vdcftna Thermostat Models REMOTE-READY Models Vdcfrna and Vdcfrpa KEY Part Numbers Vdcfrpa Vdcfrna Description QTY Accessories Receiver and HAND-HELD Remote Control KIT Ghrcb Receiver and HAND-HELD Thermostat Remote Control KIT GhrctbInformation Video For all models. Creates the sound of a real burn- ing fireService Hints Replacement PartsTechnical Service Parts Under Warranty113133-01B Warranty Information Keep this WarrantyLimited Warranty VENT-FREE Compact Classic Hearth