Desa VDCFTPA Optional HAND-HELD Remote Operation, ON/OFF Series Model Cghrcb, Manual Mode

Page 25

OPERATING FIREPLACE

Continued

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 40). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 23.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 42). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand- held remote control unit.

IMPORTANT:Do not leave the selectorswitch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

FlameControl

Adjustment Knob Knob

Selector Switch in Remote Position (Optional Remote Control)

Figure 42 - Setting the Selector Switch,

Control Knob and Flame Adjustment

Knob for Remote Operation

ON/OFF SERIES (MODEL [C]GHRCB)

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 43).

TO LOCK press both buttons on hand-held remote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

Control Button

Turns Burners

On and Off

Figure 43 - On/Off Hand-Held Remote Control Unit (GHRCB)

THERMOSTAT SERIES (MODEL [C]GHRCTB)

The hand-held remote can be operated using either the manual mode (MANU) or thermo- static mode (AUTO) (see Figure 44). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.

Digital

 

Turns

 

Hand-Held

Display

 

 

Remote On

Shows

 

 

or Off and

Temperature

Allows You

and Settings

to Choose

 

 

Turns

 

the Manual

 

Setting

Burners

On

 

or Off

 

Selects Auto

 

 

Decreases

Setting

 

Room

 

Increases

Temperature

Room

in AUTO

 

 

Temperature

Mode

 

 

in AUTO

 

 

 

Locks System to

Mode

 

 

 

Prevent Accidental

 

 

Ignition

 

Figure 44 - Thermostat Hand-Held

Remote Control Unit ([C]GHRCTB)

Manual Mode

 

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press the MANU button to turn on the fireplace.

3.Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press AUTO button to select this mode.

3.Set the desired room temperature by press- ing the TEMP + or - buttons.

4.Press the POWER and LOCK buttons together to turn off the fireplace

113133-01B

www.desatech.com

25

Image 25
Contents What to do if YOU Smell GAS Shown with Optional Cabinet Mantel/Hearth Base AccessoryTable of Contents Safety Information Safety Information Product Identification Product FeaturesLocal Codes UnpackingSheet Metal Screws Hood Louver Firebox Top Hood AssemblyTools Required Phillips screwdriver Shoulder Screw ScreenProviding Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationFireplace Clearances Installation ItemsMinimum Clearance to Combustible Materials TopActual Framing Height BUILT-IN Fireplace InstallationFront Width DepthMantel Shelf Optional Mantel InstallationSide of Firebox Top Louver Bottom LouverInstalling Optional Blower Accessory GA3450TA Switch Power Cord Installing Blower AccessoryPlate Remote Wire Blower Harness Bracket Lower Louver Door SwitchExtension Cord For Built-In InstallationBlower Bracket Connecting to GAS Supply Installation Items Needed Connecting Equipment Shutoff Valve to Heater ControlChecking GAS Connections Equipment Shutoff Valve Propane/LP Supply Tank Pressure Testing Fireplace Gas ConnectionsEquipment Open Shutoff Valve Closed Gas Regulator or Gas Control Valve EquipmentInstalling Receiver Optional Wireless HAND-HELD Remote Control AccessoriesInstalling 9-Volt Battery in Hand-Held Remote Control Unit Volt Terminal Battery Wires Battery ClipFeed wires through rectangular slots Control Valve To Wall Thermostat or Switch Or SwitchRemove jumper wire from control valve see , Terminal W Terminal R RFor Your Safety Read Before Lighting Installing LOG SET and ScreenOperating Fireplace Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Shutting Off FireplaceAUTO/OFF/ON Switch REMOTE-READY Models For Your Safety Read Before LightingOperating Blower Pilot Ignitor Burner Electrode Piezo Flame Control Ignitor Adjustment Knob ButtonPilot Burner Ignitor Electrode Auto Thermostatic Mode Manual ModeOptional HAND-HELD Remote Operation ON/OFF Series Model CghrcbSafety Features Optional GWMS2 Wall Mounted SwitchAuto Shutoff Feature Key Pad Lock FeatureInspecting Burners Cleaning MaintenanceCabinet LOG SETAir Passageways ExteriorObserved Problem Possible Cause Remedy TroubleshootingBurner orifice is clogged Burner orifice is clogged Clean burner see CleaningMote-Ready Models Only Models OnlyMote-Ready Models Only Power is low When heated, vapors fromSlight smoke or odor during Nance,Gas leak. See Warning Thermostat Models SpecificationsRemote-Ready Models Firebox Models VDC Illustrated Parts BreakdownNot a field replacement part Parts ListThermostat Models Vdcftpa and Vdcftna Thermostat Models REMOTE-READY Models Vdcfrna and Vdcfrpa KEY Part Numbers Vdcfrpa Vdcfrna Description QTY Accessories Receiver and HAND-HELD Remote Control KIT Ghrcb Receiver and HAND-HELD Thermostat Remote Control KIT GhrctbInformation Video For all models. Creates the sound of a real burn- ing fireService Hints Replacement PartsTechnical Service Parts Under Warranty113133-01B Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Compact Classic Hearth