Desa VDCFRNA, VDCFRPA Optional GWMT1 Wall Mounted Thermostat, Optional GWMS2 Wall Mounted Switch

Page 26

OPERATING FIREPLACE

Continued

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace.

Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.

Safety Features

When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Auto Shutoff Feature

1.If the average room temperature exceeds 82 degrees Fahrenheit (28 degrees Centi- grade), the hand-held remote control will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

2.The receiver continuously receives signals from the hand-held remote to control the room temperature. If the hand-held remote is misplaced, obstructed or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

Key Pad Lock Feature

This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held remote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

OPTIONAL GWMT1 WALL

MOUNTED THERMOSTAT

Make sure the heater switch is on AUTO and set the temperature adjustment on wall thermostat to the desired setting. The thermostat has been electronically calibrated at the factory and re- quires no adjustment or leveling.

Upon installation, the thermostat must be al- lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation. See installation instructions on pages 19 and 20.

OPTIONAL GWMS2 WALL

MOUNTED SWITCH

Make sure the heater switch is on AUTO. This wall switch works just like the conventional light switch. Flip the switch up for on and down for off.

Note: Make sure that this switch is not in a posi- tion to be mistaken for a light switch. This may result in the fireplace being inadvertently turned on without the proper precautions being taken. See installation instructions on page 19.

OPERATING

BLOWER

This blower has three settings: ON, OFF and AUTO. In the ON position, the blower will oper- ate constantly. In the OFF position, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient increase in firebox temperature.

Note: Your fireplace and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace.

AUTO/OFF/ON Switch

Figure 45 - AUTO/OFF/ON Blower Switch

26

www.desatech.com

113133-01B

Image 26
Contents Shown with Optional Cabinet Mantel/Hearth Base Accessory What to do if YOU Smell GASTable of Contents Safety Information Safety Information Local Codes Product FeaturesProduct Identification UnpackingTools Required Phillips screwdriver Hood AssemblySheet Metal Screws Hood Louver Firebox Top Shoulder Screw ScreenDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationProviding Adequate Ventilation Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Check GAS TypeMinimum Clearance to Combustible Materials Installation ItemsFireplace Clearances TopFront Width BUILT-IN Fireplace InstallationActual Framing Height DepthSide of Firebox Optional Mantel InstallationMantel Shelf Top Louver Bottom LouverInstalling Optional Blower Accessory GA3450TA Plate Remote Wire Blower Harness Bracket Lower Louver Door Installing Blower AccessorySwitch Power Cord SwitchBlower Bracket For Built-In InstallationExtension Cord Connecting to GAS Supply Checking GAS Connections Connecting Equipment Shutoff Valve to Heater ControlInstallation Items Needed Equipment Open Shutoff Valve Closed Pressure Testing Fireplace Gas ConnectionsEquipment Shutoff Valve Propane/LP Supply Tank Gas Regulator or Gas Control Valve EquipmentInstalling 9-Volt Battery in Hand-Held Remote Control Unit Optional Wireless HAND-HELD Remote Control AccessoriesInstalling Receiver Volt Terminal Battery Wires Battery ClipRemove jumper wire from control valve see , Control Valve To Wall Thermostat or Switch Or SwitchFeed wires through rectangular slots Terminal W Terminal R ROperating Fireplace Installing LOG SET and ScreenFor Your Safety Read Before Lighting Lighting InstructionsThermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off FireplaceOperating Blower REMOTE-READY Models For Your Safety Read Before LightingAUTO/OFF/ON Switch Pilot Burner Ignitor Electrode Piezo Flame Control Ignitor Adjustment Knob ButtonPilot Ignitor Burner Electrode Optional HAND-HELD Remote Operation Manual ModeAuto Thermostatic Mode ON/OFF Series Model CghrcbAuto Shutoff Feature Optional GWMS2 Wall Mounted SwitchSafety Features Key Pad Lock FeatureCleaning Maintenance Inspecting BurnersAir Passageways LOG SETCabinet ExteriorTroubleshooting Observed Problem Possible Cause RemedyMote-Ready Models Only Burner orifice is clogged Clean burner see CleaningBurner orifice is clogged Models OnlySlight smoke or odor during When heated, vapors fromMote-Ready Models Only Power is low Nance,Gas leak. See Warning Remote-Ready Models SpecificationsThermostat Models Illustrated Parts Breakdown Firebox Models VDCParts List Not a field replacement partThermostat Models Vdcftpa and Vdcftna Thermostat Models REMOTE-READY Models Vdcfrna and Vdcfrpa KEY Part Numbers Vdcfrpa Vdcfrna Description QTY Accessories Information Video Receiver and HAND-HELD Thermostat Remote Control KIT GhrctbReceiver and HAND-HELD Remote Control KIT Ghrcb For all models. Creates the sound of a real burn- ing fireTechnical Service Replacement PartsService Hints Parts Under Warranty113133-01B Limited Warranty VENT-FREE Compact Classic Hearth Warranty InformationKeep this Warranty