Desa VC42N SERIES, VC42P SERIES REMOVING/REPLACING Glass Door, Installing Remote Receiver

Page 21

FIREPLACE INSTALLATION

Installing Optional Wireless Hand-Held Remote Control - GHRCB and GHRCTB Series Removing/Replacing Glass Door

21

FIREPLACE INSTALLATION

Continued

INSTALLING OPTIONAL WIRELESS HAND- HELD REMOTE CONTROL - GHRCB AND GHRCTB SERIES

NOTICE: Use only alkaline batteries (not included).

Installing Remote Receiver

1.Open bottom louver and locate the switch bracket on the left.

2.Unscrew the switch bracket. Lean bracket forward so you are able to access the back of the remote receiver.

3.Locate the battery clip mounted on the back of the receiver. Slide a 9-volt alkaline battery (not included) through the clip (see Figure 37).

4.Attach the terminal wires to the battery.

5.Connect wires from receiver to TH and TPTH to control valve (see Figure 38).

6.Replace the switch bracket.

Receiver

9-Volt Alkaline

Battery

Terminal Wires

Battery Clip

Figure 37 - Attaching Alkaline Battery to Receiver

To Optional

Remote

Accessory

Figure 38 - Control Valve Terminals

Installing 9-Volt Alkaline Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to a 9-volt alkaline battery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote control unit.

Battery Cover

Remote Control Unit

Terminal

 

Wires

 

9-Volt

 

Alkaline

Battery

Battery

Housing

 

Figure 39 - Installing Alkaline Battery in Hand-Held Remote

Control Unit (GHRCB)

 

9-Volt

Terminal

Wires

Battery

Remote

 

 

Control

 

Unit

 

Battery

 

Cover

Figure 40 - Installing Battery in Hand-Held Remote Control Unit

(GHRCTB Series)

 

REMOVING/REPLACING GLASS DOOR

CAUTION: Do not operate this fireplace with a

broken glass door panel or without the glass door

panel securely in place. For replacement part infor-

mation see Replacement Parts, page 31.

CAUTION: Wear gloves and safety glasses while

handling or removing broken glass. Do not remove if

glass is hot. Keep children and pets away from glass.

WARNING: If fireplace has been running, turn

off and unplug fireplace. Let cool before removing

glass door or louvers.

 

Removing Louver Panels

Remove the top and bottom louver panels by simultaneously pulling

both top end spring latches towards the center of the appliance until

they are disengaged from the locating holes (see Figure 41). Repeat

for bottom spring latches and pull the louvers outward. To install or

replace items removed, simply reverse the procedures above.

Louver Panel

Spring Latch

Figure 41 - Removing Louver Panel

116236-01A

www.desatech.com

Image 21
Contents For Your Safety For Your Safety What to do if YOU Smell GASSave this manual for future reference Safety Information Table of ContentsLocal Codes Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Framing and Finishing ClearancesTermination CAP AIR Supply Inlet GAS Meter Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Combustible Vertical Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationFireplace Installation Venting InstallationInstalling Optional Blower Accessories Check GAS TypeBlower see Figure Model BKT InstallationInstalling GAS Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Connecting Fireplace to GAS Supply Checking GAS ConnectionsOr servicing. Correct all leaks at once Pressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Installing Remote Receiver REMOVING/REPLACING Glass DoorRemoving Louver Panels Installing Lava Rock and Glowing Embers Cleaning Glass DoorRemoving Glass Doors For Your Safety Read Before Lighting Installing Brick Liner Models BL42DASA and BL42 DhasaOperating Fireplace Lighting InstructionsTo Turn OFF GAS Manual Lighting ProcedureTo Appliance Optional HAND-HELD Remote OperationManual Mode Safety FeaturesAuto Thermostatic Mode ON/OFF Series Model GhrcbPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause Remedy TroubleshootingBrick Liner Models BL42DASA Above Gas leak. See Warning statementService Hints Replacement PartsTechnical Service SpecificationsModels VC42N, VC42P, VVC42N and VVC42P Series Illustrated Parts BreakdownKEY Part Number Description QTY Parts List19 18 Parts List Accessories Owners Registration Form Postage Required 116236-01A Warranty Information

VC42N SERIES, VC42P SERIES specifications

Desa VC42P SERIES and VC42N SERIES represent a significant evolution in the realm of heating technology, particularly in the context of modern residential and commercial applications. Designed for efficiency, these products integrate advanced features and innovative technologies that cater to the diverse needs of users seeking reliable heating solutions.

One of the main features of the VC42P SERIES is its high-efficiency performance, achieving exceptional heating output while minimizing energy consumption. This is largely due to its advanced combustion technology, which ensures thorough fuel utilization and significantly reduces emissions. The VC42N SERIES, on the other hand, emphasizes versatile applications, providing a flexible heating option suitable for various environments, including garages, workshops, and large living spaces.

Both series are designed with user-friendly controls, allowing for precise temperature adjustments and easy operation. The intuitive digital thermostat enhances the user experience, enabling personalized comfort settings. In addition, the units come equipped with a built-in timer for programmable heating schedules, promoting energy savings by allowing users to heat spaces only when needed.

Another notable characteristic of the Desa VC42P and VC42N SERIES is their robust construction and durability. Built with high-quality materials, these heaters are designed to withstand everyday wear and tear, ensuring long-lasting performance. This makes them ideal for both residential and commercial use, where reliability is paramount.

The technology behind these heaters also includes safety features such as tip-over protection and overheat sensors, which automatically shut off the unit in unsafe conditions. This not only protects the heater but also contributes to peace of mind for the user, especially in environments with children or pets.

In terms of design, both series boast sleek and modern aesthetics, seamlessly integrating into various interior styles. Their compact size allows for easy placement in different spaces without compromising on heating performance.

Overall, the Desa VC42P SERIES and VC42N SERIES reflect a commitment to innovative heating solutions, blending efficiency, safety, and user-centric design. These heaters not only provide effective warmth but also contribute to reducing environmental impact, making them an excellent choice for environmentally conscious consumers. Whether for daily comfort or specific project needs, these series are engineered to meet and exceed expectations, setting a new standard in heating technology.