Desa VC42P SERIES, VC42N SERIES Installing Lava Rock and Glowing Embers, Removing Glass Doors

Page 22

 

FIREPLACE INSTALLATION

22

Removing/Replacing Glass Door (Cont.)

 

 

Installing Lava Rock and Glowing Embers

 

 

FIREPLACE INSTALLATION

Continued

Removing Glass Doors

If replacement of glass is necessary, the entire assembly, glass and frame, must be replaced. If glass is broken, wear gloves and tape the remaining fragments onto the frame.

1.Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen/rod assembly from the firebox. Set assembly aside.

2.Lift up on latches to unlock. There are two on top of firebox and two below firebox that hold glass door in place (see Figure 42).

3.While holding glass door to prevent it from falling and causing injury, remove the five screws from the hinge located on the left side of door frame assembly (see Figure 42).

4.Remount the new frame at the hinge with five new screws before closing door. This will ensure seating of the gasket.

5.Close glass door frame. Lock latches by placing the bar under the tab on door and pushing down and back on latch (see Figure 42).

6.Replace screen/rod assembly by reversing step 1.

7.Replace louvers by reversing procedure under Removing Louver Panels, page 21.

Unlock Lock

Latch

Screw

Hinge

Glass Frame

Assembly

Figure 42 - Removing/Replacing Glass Door

INSTALLING LAVA ROCK AND GLOWING EMBERS

It is very important to keep logs exactly as installed. Do not modify logs. Only use log set designed for this fireplace. Logs under log/grate assembly are attached to burner. Do not attempt to move these logs as this will damage logs.

WARNING: Logs are unitized and attached to the grate. Do not handle log/grate assembly by logs. Always pick up by grate.

Open louvers, remove screen, unlock door latches and open glass door. See Removing Glass Door, steps 1 and 2.

1.Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto the exposed front section of the burner (see Figure 43). This will create the glow- ing ember appearance as the flame touches the ember material. Do not block air slots by using too much ember material in one area. It is not necessary to use all of the ember material provided.

2.Pour lava rock onto plenum but not onto flat burner. It is not necessary to use all of the lava rock provided.

NOTICE: Do not put lava rock on burner or under burner. Placing lava rock on burner will cause per- formance problems.

3.Close glass door, lock door latches, replace screen and close louvers (see Removing Glass Door, steps 5 through 7).

WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken.

Plenum

Embers

Cleaning Glass Door

Figure 43 - Placing Ember Material on Burner

See Cleaning and Maintenance on page 27.

 

www.desatech.com

116236-01A

Image 22
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySave this manual for future reference Table of Contents Safety InformationProduct Identification Local CodesPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Siding Standoff Combustible Horizontal Termination Configurations Vertical Horizontal HCorner Installation Horizontal System Installation Using TWO Elbows Venting with Two 90 ElbowsInstallation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Venting with One 90 ElbowHigh Altitude Installation Vertical VentingInstalling Optional Blower Accessories Venting InstallationFireplace Installation Check GAS TypeModel BKT Installation Blower see FigureBlower Wiring Diagram Installing GAS Piping to Fireplace LocationInstallation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyOr servicing. Correct all leaks at once Installing Optional Wall Mount Switch GWMS2 Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Installing Remote ReceiverRemoving Louver Panels Cleaning Glass Door Installing Lava Rock and Glowing EmbersRemoving Glass Doors Operating Fireplace Installing Brick Liner Models BL42DASA and BL42 DhasaFor Your Safety Read Before Lighting Lighting InstructionsTo Appliance Manual Lighting ProcedureTo Turn OFF GAS Optional HAND-HELD Remote OperationAuto Thermostatic Mode Safety FeaturesManual Mode ON/OFF Series Model GhrcbInspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible Cause RemedyBrick Liner Models BL42DASA Gas leak. See Warning statement AboveTechnical Service Replacement PartsService Hints SpecificationsIllustrated Parts Breakdown Models VC42N, VC42P, VVC42N and VVC42P SeriesParts List KEY Part Number Description QTY19 18 Parts List Accessories Owners Registration Form Postage Required 116236-01A Warranty Information

VC42N SERIES, VC42P SERIES specifications

Desa VC42P SERIES and VC42N SERIES represent a significant evolution in the realm of heating technology, particularly in the context of modern residential and commercial applications. Designed for efficiency, these products integrate advanced features and innovative technologies that cater to the diverse needs of users seeking reliable heating solutions.

One of the main features of the VC42P SERIES is its high-efficiency performance, achieving exceptional heating output while minimizing energy consumption. This is largely due to its advanced combustion technology, which ensures thorough fuel utilization and significantly reduces emissions. The VC42N SERIES, on the other hand, emphasizes versatile applications, providing a flexible heating option suitable for various environments, including garages, workshops, and large living spaces.

Both series are designed with user-friendly controls, allowing for precise temperature adjustments and easy operation. The intuitive digital thermostat enhances the user experience, enabling personalized comfort settings. In addition, the units come equipped with a built-in timer for programmable heating schedules, promoting energy savings by allowing users to heat spaces only when needed.

Another notable characteristic of the Desa VC42P and VC42N SERIES is their robust construction and durability. Built with high-quality materials, these heaters are designed to withstand everyday wear and tear, ensuring long-lasting performance. This makes them ideal for both residential and commercial use, where reliability is paramount.

The technology behind these heaters also includes safety features such as tip-over protection and overheat sensors, which automatically shut off the unit in unsafe conditions. This not only protects the heater but also contributes to peace of mind for the user, especially in environments with children or pets.

In terms of design, both series boast sleek and modern aesthetics, seamlessly integrating into various interior styles. Their compact size allows for easy placement in different spaces without compromising on heating performance.

Overall, the Desa VC42P SERIES and VC42N SERIES reflect a commitment to innovative heating solutions, blending efficiency, safety, and user-centric design. These heaters not only provide effective warmth but also contribute to reducing environmental impact, making them an excellent choice for environmentally conscious consumers. Whether for daily comfort or specific project needs, these series are engineered to meet and exceed expectations, setting a new standard in heating technology.