Desa VC42P SERIES Inspecting Burners, Operating Optional GWMT1 Wall Mounted Thermostat

Page 26

26

OPERATING FIREPLACE

Operating Optional GWMT1 Wall Mounted Thermostat

 

Operating Optional Blower Accessory

 

INSPECTING BURNERS

 

Pilot Assembly

 

Burner Flame Pattern

 

 

OPERATING FIREPLACE

Continued

OPERATING OPTIONAL GWMT1

WALL MOUNTED THERMOSTAT

WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire hazard will occur.

Light the fireplace as instructed in Lighting Instructions on page 23. Set wall thermostat to desired temperature.

This thermostat has been electronically calibrated at the factory and requires no adjustment or leveling.

Upon installation, the thermostat must be allowed to stabilize at room temperature for a minimum of 30 minutes for proper operation.

To turn the fireplace off, adjust thermostat to the lowest set- ting and turn the gas control knob back to PILOT. The pilot will remain lit.

IMPORTANT: To turn the pilot off, turn the gas control knob on the heater to the OFF position.

OPERATING OPTIONAL

BLOWER ACCESSORY

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the right side of the switch bracket to the left just inside the louver panel.

The BK manual blowerand the BKTthermostatically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time.The fireplace may run forseveral minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

The blower helps distribute heated air from the fireplace. Peri- odically check the louvers of the firebox and remove any dust, dirt or other obstructions that will hinder the flow of air.

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary.

The height of the thermopile must be 3/8" to 1/2" above the pilot flame as shown in Figure 49. The thermocouple must be at a height of about 1/8" above the pilot flame. The flame from the pilot burner must extend beyond both the thermocouple and thermopile.

If you pilot assembly does not meet these requirements:

turn fireplace off (see To Turn Off Gas to Appliance, page 24)

see Troubleshooting, page 28

3/8" to 1/2"

Pilot Burner

Thermopile

1/8"

Thermocouple

Piezo

Ignitor

Figure 49 - Pilot Assembly

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on instal- lation type and weather conditions.

If the vent configuration is installed incorrectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after instal- lation to ensure proper installation and performance.

Figure 50 shows a typical flame pattern.

If burner flame pattern differs from that described:

turn fireplace off (see To Turn Off Gas to Appliance, page 24)

see Troubleshooting, page 28

Figure 50 - Typical Flame Pattern

www.desatech.com

116236-01A

Image 26
Contents Save this manual for future reference For Your SafetyFor Your Safety What to do if YOU Smell GAS Table of Contents Safety InformationProduct Identification Local CodesLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Clearances Framing and FinishingLocation of Termination CAP Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Horizontal Termination InstallationInstalling Siding Standoff Combustible Horizontal Termination Configurations Vertical Horizontal HCorner Installation Horizontal System Installation Using TWO Elbows Venting with Two 90 ElbowsInstallation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Venting with One 90 ElbowHigh Altitude Installation Vertical VentingInstalling Optional Blower Accessories Venting InstallationFireplace Installation Check GAS TypeModel BKT Installation Blower see FigureInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Or servicing. Correct all leaks at once Connecting Fireplace to GAS SupplyChecking GAS Connections Installing Optional Wall Mount Switch GWMS2 Pressure Testing Fireplace Gas ConnectionsRemoving Louver Panels Installing Remote ReceiverREMOVING/REPLACING Glass Door Removing Glass Doors Installing Lava Rock and Glowing EmbersCleaning Glass Door Operating Fireplace Installing Brick Liner Models BL42DASA and BL42 DhasaFor Your Safety Read Before Lighting Lighting InstructionsTo Appliance Manual Lighting ProcedureTo Turn OFF GAS Optional HAND-HELD Remote OperationAuto Thermostatic Mode Safety FeaturesManual Mode ON/OFF Series Model GhrcbInspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible Cause RemedyBrick Liner Models BL42DASA Gas leak. See Warning statement AboveTechnical Service Replacement PartsService Hints SpecificationsIllustrated Parts Breakdown Models VC42N, VC42P, VVC42N and VVC42P SeriesParts List KEY Part Number Description QTY19 18 Parts List Accessories Owners Registration Form Postage Required 116236-01A Warranty Information

VC42N SERIES, VC42P SERIES specifications

Desa VC42P SERIES and VC42N SERIES represent a significant evolution in the realm of heating technology, particularly in the context of modern residential and commercial applications. Designed for efficiency, these products integrate advanced features and innovative technologies that cater to the diverse needs of users seeking reliable heating solutions.

One of the main features of the VC42P SERIES is its high-efficiency performance, achieving exceptional heating output while minimizing energy consumption. This is largely due to its advanced combustion technology, which ensures thorough fuel utilization and significantly reduces emissions. The VC42N SERIES, on the other hand, emphasizes versatile applications, providing a flexible heating option suitable for various environments, including garages, workshops, and large living spaces.

Both series are designed with user-friendly controls, allowing for precise temperature adjustments and easy operation. The intuitive digital thermostat enhances the user experience, enabling personalized comfort settings. In addition, the units come equipped with a built-in timer for programmable heating schedules, promoting energy savings by allowing users to heat spaces only when needed.

Another notable characteristic of the Desa VC42P and VC42N SERIES is their robust construction and durability. Built with high-quality materials, these heaters are designed to withstand everyday wear and tear, ensuring long-lasting performance. This makes them ideal for both residential and commercial use, where reliability is paramount.

The technology behind these heaters also includes safety features such as tip-over protection and overheat sensors, which automatically shut off the unit in unsafe conditions. This not only protects the heater but also contributes to peace of mind for the user, especially in environments with children or pets.

In terms of design, both series boast sleek and modern aesthetics, seamlessly integrating into various interior styles. Their compact size allows for easy placement in different spaces without compromising on heating performance.

Overall, the Desa VC42P SERIES and VC42N SERIES reflect a commitment to innovative heating solutions, blending efficiency, safety, and user-centric design. These heaters not only provide effective warmth but also contribute to reducing environmental impact, making them an excellent choice for environmentally conscious consumers. Whether for daily comfort or specific project needs, these series are engineered to meet and exceed expectations, setting a new standard in heating technology.