Desa VC42N SERIES, VC42P SERIES installation manual Clearances, Framing and Finishing

Page 5

PRE-INSTALLATION PREPARATION

Clearances

Framing and Finishing

5

PRE-INSTALLATION

PREPARATION

Continued

CLEARANCES

Minimum clearances to combustibles for the fireplace are as follows:

For available accessories for this fireplace, see Accessories on page

36.If you are using a separate combustible mantel piece, refer to Figure 6 for proper installation height. You can install noncombus- tible mantels at any height above the fireplace.

Note: Noncombustible mantels may discolor!

*Back and sides

0"/mm

Perpendicular walls

6" (152mm)

Floor

0"/mm

Ceiling to louver opening

42" (1067mm)

Front

36" (914mm)

Top of Standoffs

0"/mm

Vent

(See venting instructions for

 

specific venting clearances.)

Combustible material with a maximum thickness of 5/8" may be flush with the top front of fireplace.

*For back and sides of fireplace, do not pack with insulation or other materials. Zero inch clearance to combustible materials are for framing purpose only.

21

5/8"

13 1/2"

41 5/8"

16 3/4"

48" 48 1/4"

81 1/2"

58 1/2"

Nailing Tabs

NOTICE: This fireplace is intended for use as supple- mental heat. Use this fireplace along with your primary heating system. Do not install this fireplace as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using fireplace. This will help circulate the heat throughout the house. In the event of a power outage, you can use this fireplace as a heat source.

FRAMING AND FINISHING

Figure 4 shows typical framing of this fireplace. Figure 5 shows fram- ing for corner installation. All minimum clearances must be met.

40 1/8"

48 1/4"

25 5/8"

Figure 5 - Framing Clearances for Corner Installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

Wall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of Louver Opening

 

 

 

 

 

 

 

 

 

Ref.

Mantel Depth

Ref.

Mantel from Top

 

 

 

 

 

 

 

 

 

 

 

 

 

of Louver Opening

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

14" (356mm)

 

A

 

 

 

16" (406mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

12" (305mm)

 

B

 

 

 

14" (356mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

10" (254mm)

 

C

 

 

 

12" (305mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

8" (203mm)

 

D

 

 

 

10" (254mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

6" (152mm)

 

E

 

 

 

8" (203mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

4" (101mm)

 

F

 

 

 

6" (152mm)

 

 

 

 

7

2" (51mm)

 

G

 

 

 

4" (101mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 6 - Clearances for Combustible Mantels

Figure 4 - Framing Clearances for Installation Against an Exterior Wall

116236-01A

www.desatech.com

Image 5
Contents Save this manual for future reference For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesTermination CAP AIR Supply Inlet GAS Meter Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Combustible Vertical Horizontal H Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationFireplace Installation Venting InstallationInstalling Optional Blower Accessories Check GAS TypeBlower see Figure Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Or servicing. Correct all leaks at once Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Removing Louver Panels Installing Remote ReceiverREMOVING/REPLACING Glass Door Removing Glass Doors Installing Lava Rock and Glowing EmbersCleaning Glass Door For Your Safety Read Before Lighting Installing Brick Liner Models BL42DASA and BL42 DhasaOperating Fireplace Lighting InstructionsTo Turn OFF GAS Manual Lighting ProcedureTo Appliance Optional HAND-HELD Remote OperationManual Mode Safety FeaturesAuto Thermostatic Mode ON/OFF Series Model GhrcbPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause Remedy TroubleshootingBrick Liner Models BL42DASA Above Gas leak. See Warning statementService Hints Replacement PartsTechnical Service SpecificationsModels VC42N, VC42P, VVC42N and VVC42P Series Illustrated Parts BreakdownKEY Part Number Description QTY Parts List19 18 Parts List Accessories Owners Registration Form Postage Required 116236-01A Warranty Information

VC42N SERIES, VC42P SERIES specifications

Desa VC42P SERIES and VC42N SERIES represent a significant evolution in the realm of heating technology, particularly in the context of modern residential and commercial applications. Designed for efficiency, these products integrate advanced features and innovative technologies that cater to the diverse needs of users seeking reliable heating solutions.

One of the main features of the VC42P SERIES is its high-efficiency performance, achieving exceptional heating output while minimizing energy consumption. This is largely due to its advanced combustion technology, which ensures thorough fuel utilization and significantly reduces emissions. The VC42N SERIES, on the other hand, emphasizes versatile applications, providing a flexible heating option suitable for various environments, including garages, workshops, and large living spaces.

Both series are designed with user-friendly controls, allowing for precise temperature adjustments and easy operation. The intuitive digital thermostat enhances the user experience, enabling personalized comfort settings. In addition, the units come equipped with a built-in timer for programmable heating schedules, promoting energy savings by allowing users to heat spaces only when needed.

Another notable characteristic of the Desa VC42P and VC42N SERIES is their robust construction and durability. Built with high-quality materials, these heaters are designed to withstand everyday wear and tear, ensuring long-lasting performance. This makes them ideal for both residential and commercial use, where reliability is paramount.

The technology behind these heaters also includes safety features such as tip-over protection and overheat sensors, which automatically shut off the unit in unsafe conditions. This not only protects the heater but also contributes to peace of mind for the user, especially in environments with children or pets.

In terms of design, both series boast sleek and modern aesthetics, seamlessly integrating into various interior styles. Their compact size allows for easy placement in different spaces without compromising on heating performance.

Overall, the Desa VC42P SERIES and VC42N SERIES reflect a commitment to innovative heating solutions, blending efficiency, safety, and user-centric design. These heaters not only provide effective warmth but also contribute to reducing environmental impact, making them an excellent choice for environmentally conscious consumers. Whether for daily comfort or specific project needs, these series are engineered to meet and exceed expectations, setting a new standard in heating technology.