Desa VP325E(B) installation manual Combustion AIR KIT Model AK4 Optional, Appliance Enclosure

Page 14

14

INSTALLATION

Combustion Air Kit Model AK4 (Optional)

Appliance Enclosure

Installing Optional Glass Door Accessory

INSTALLATION

Continued

COMBUSTION AIR KIT MODEL AK4 (OPTIONAL)

The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through the outside wall or a ventilated crawl space. The handle to operate the damper door for the outside air inlet will be located inside the left “screen pocket” of the firebox (see Figure 29). Pull the handle to open or push to close.

CAUTION: Air inlet ducts are not to terminate in attic space.

Screen Pocket

Air Kit

Handle

Figure 29 - Air Kit Handle Location

APPLIANCE ENCLOSURE

Before finishing the enclosure around the appliance, inspect all joints around the outer surround. Any gaps between the nailing flanges and the framing should be sealed with noncombustible insulation or caulking (see Figure 30).

If the appliance is mounted on a raised platform, it must be a continuous surface and not on blocks without a solid surface. This will prevent the entry of cold air by means of conduction through the total bottom of the appliance.

Side

 

 

Side

Framing

 

 

Framing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Caulk Here

Pack Insulation

Figure 30 - Sealing Between Appliance and Framing

INSTALLING OPTIONAL GLASS DOOR ACCESSORY

CAUTION: Use only glass doors certified for use with this appliance.

Note: Glass door may be heavy for some individuals. If this is the case, please request help from someone else.

These B-vent fireplaces are approved for use with optional bi-fold glass doors (see Accessories, page 21). The glass doors may be ordered and installed anytime after the fireplace installation is complete.

Installing Glass Doors

1.With the handle at the bottom, completely fold the panel on its hinges.

2.With the handle facing the center of the firebox opening, insert the lower pivot pin on the glass door panel into the hole in pivot plate on the bottom edge of the fireplace opening (see Figure 31).

3.Keeping the folded door tilted, slide the upper two pins into the guide track found under the upper facial edge of the fire- box opening.

4.Tilt the door assembly fully vertical until the outer pivot pin snaps into the mounting hole in the upper spring clip (see Figure 31).

5.Once the top and bottom pins are secured, unfold the door into the closed position.

6.Repeat the process for the opposite door assembly.

7.To adjust the doors, slide them partially open. Using a screw- driver, loosen the hold-down screws in the spring clip (see Fig- ure 32, page 15) and pivot plate.

Slide Top Pin

Spring Clip

Into Door Track

 

Insert Pin Into

Spring Clip

Insert Bottom

Pivot Pin Into

Pivot Plate and

Swing Door Into

Vertical Position

Pivot Plate

Figure 31 - Installing Optional Glass Door

For morevisit www..com

108794-01D

Image 14
Contents Natural GAS For Your SafetyVent Decorative GAS Fireplace What to do if YOU Smell GASTable of Contents Safety InformationUnpacking Introduction Before YOU BeginProduct Specifications Selecting LocationMantel Clearances and Wall Details PRE-INSTALLATION PreparationClearances Corner Installation Guidelines FramingVenting Installation Typical B-Vent ConfigurationChecking for Proper Venting Min Roof PitchOptional Remote Control InstallationWall Switch Installation GAS Line HOOK-UPGrate Placement Not SuppliedEmber and PAN Material Placement LOG Placement for P324E/VP324E ModelsLOG Placement for P325EB/VP325EB Modles Installing LogAppliance Enclosure Installing Optional Glass Door AccessoryCombustion AIR KIT Model AK4 Optional Lighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To Appliance Pilot AssemblyInspecting Burners Optional Remote OperationPilot and Burner Cleaning MaintenanceBurner Flame Pattern LogsWiring Diagram Replacement Parts Service HintsTechnical Service Parts Under WarrantyTroubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning statement at Accessories Illustrated Parts Breakdown Parts List P324E and VP324E ModelsIllustrated Parts BREAKDOWN44 P325EB and VP325EB Models108866-01 Pilot Natural Gas 901157-01 Lava Rock LOG Assembly Illustrated Parts BreakdownOwners Registration Form Postage Required 108794-01D Warranty Information