Desa VP325E(B) installation manual Framing, Corner Installation Guidelines

Page 7

PRE-INSTALLATION PREPARATION

Framing

7

PRE-INSTALLATION

PREPARATION

Continued

FRAMING

1.Frame appliance enclosure as illustrated in Figures 7 and 8.

Note: If a wall covering is used to line the enclosure, then all measurements must be from the surface of the covering.

2.Place the appliance into the framing and secure it.

Note: If appliance is to be raised above floor level, a platform must be built to support the appliance.

3.Install the supply line to the appliance using a 1/2" NPT black iron gas line terminating 2 5/16" above the bottom of the appli- ance. The gas line may be installed from either side or from the rear of the appliance (see Figure 16, page 11).

4.Feed flexible gas line through one of three gas line conduit sleeve and repack insulation to cover any openings. Prepare the incoming gas line with teflon tape or pipe joint compound and hook-up incoming gas line to the flexible gas line.

Note: If 1/2" NPT black iron pipe does not mate with fitting at the end of flexible gas line, remove fitting and replace with a 37 degree flare 3/4"-12, 1/2" NPT (female) fitting.

WARNING: When finishing appliance, do not overlap combustible material onto the black front face. Brick,tile, or other noncombustible materials may be applied to the face provided that any gap is between the material used and the face is caulked with a noncombustible caulking.

These Dimensions Allow for a 3/4" Clearance at Sides and Back of Fireplace. However, 0" Clearance is Permitted

12"

393/8"

16 3/4"

 

16"

55 5/8"

3/4" Clearance

Not Required

34 1/2"

at Nailing

 

Flanges

Figure 8 - Corner Installation Guidelines

36 5/8"

16 1/8"

34 3/4"

Figure 7 - Rough Opening for Installing in Wall

For more information, visit www.desatech.com

108794-01D

Image 7
Contents What to do if YOU Smell GAS For Your SafetyVent Decorative GAS Fireplace Natural GASSafety Information Table of ContentsUnpacking Before YOU Begin IntroductionSelecting Location Product SpecificationsClearances PRE-INSTALLATION PreparationMantel Clearances and Wall Details Framing Corner Installation GuidelinesTypical B-Vent Configuration Venting InstallationMin Roof Pitch Checking for Proper VentingGAS Line HOOK-UP InstallationWall Switch Installation Optional Remote ControlNot Supplied Grate PlacementLOG Placement for P324E/VP324E Models Ember and PAN Material PlacementInstalling Log LOG Placement for P325EB/VP325EB ModlesCombustion AIR KIT Model AK4 Optional Installing Optional Glass Door AccessoryAppliance Enclosure Operating Fireplace For Your Safety Read Before LightingLighting Instructions Optional Remote Operation Pilot AssemblyInspecting Burners To Turn OFF GAS To ApplianceLogs Cleaning MaintenanceBurner Flame Pattern Pilot and BurnerParts Under Warranty Service HintsTechnical Service Wiring Diagram Replacement PartsObserved Problem Possible Cause Remedy TroubleshootingGas leak. See Warning statement at Accessories Illustrated Parts Breakdown P324E and VP324E Models Parts ListP325EB and VP325EB Models Illustrated Parts BREAKDOWN44108866-01 Pilot Natural Gas 901157-01 Lava Rock Illustrated Parts Breakdown LOG AssemblyOwners Registration Form Postage Required 108794-01D Warranty Information