Desa VVSR18 installation manual Troubleshooting, To Turn OFF GAS To Appliance

Page 13

OWNER’S MANUAL

OPERATING

APPLIANCE

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Appliance

1.Turn control knob clockwise to the PILOT position.

2.Press in and turn control clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

TROUBLESHOOTING

Note: For additional help, visit DESA International’s Technical Service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off log set and let cool before servicing. Only a qualified service person should service and repair log set.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Log set is smoking/sooting excessively

1.

Poor fuel quality

1.

Contact local natural or propane/LP gas

(Note: It is natural and unavoidable for

 

 

 

company

vented gas log sets to produce moderate

2.

Fireplace venting system not drafting

2.

Adjust damper wide open and/or have

levels of carbon (soot) where flames

 

properly

 

fireplace and venting professionally

contact the logs. This is especially true

 

 

 

cleaned and checked

with propane/LP gas.)

3.

Excessive flame impingement or

3.

Separate the logs to allow more flame

 

 

blockage

 

passage

 

4.

Improper fuel/air mixture

4.

Remove any foreign items from the

 

 

 

 

flame pattern and/or check for proper

 

 

 

 

orifice sizing

 

5.

Excessive gas supply/pressure

5.

Preheat flue in very cold weather

Burner is excessively noisy

(Note: The movement and combustion of gas will create low, unavoidable levels of noise.)

1.Passage of air/gas across irregular sur- faces

1.Relieve any tight bends or kinks in gas supply line

Burner flame is too low or too high

1.

Incorrect gas supply or pressure

1.

Check for proper gas supply pressure

 

2.

Blocked burner orifice or burner mani-

2.

Free burner orifice and manifold ports

 

 

fold ports

 

of any burrs, paint, or other blockage

 

3.

Improper burner orifice size

3.

Verify proper burner orifice sizing (see

 

 

 

 

Figure 4, page 7)

www.desatech.com

Continued

901265

13

Image 13
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Use with Log Sets Vented Natural GAS Logs Safety InformationON/OFF Safety VALVE/ Pilot KIT and PROPANE/LP Conversion Product Identification Optional Product FeaturesRemote Control Ready Millivolt Safety VALVE/ Pilot KIT Remote Control AccessoriesProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Appliance Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsFlue Opening Specifications InstallationVenting Specifications for Installation Check GAS TypeConnecting to GAS Supply Installing Damper ClampInstallation Items Needed Pressure Testing Gas Supply Piping SystemOptional GA9000 ON/OFF Safety VALVE/PILOT KIT Assembly Hearth KIT Assembly and InstallationKit Assembly Installation and Gas ConnectionBurner Inlet Fitting Propane/LP Gas ConversionInstalling the Grate and Logs Testing Burner for LeaksAdding PAN Material Changing Pilot OrificeOperating Appliance To Turn OFF GAS To Appliance TroubleshootingShutting Off Burner Only pilot stays lit Clean pilot see Cleaning and Mainte Gas leak. See Warning statement at TopVVSR18, VVSR24, VVDR18, VVDR24, and VVDR30 Illustrated Parts BreakdownVVSR18 VVSR24, VVDR18 VVDR24, and VVDR30 Parts ListLOG SET Models VSLR18, VSLR24, VDLCR18, VDLCR24, and VDLCR30 Parts List Replacement Parts Cleaning and MaintenanceAccessories Ornamental Grate Enhancer GA9310 Decorative ASH BED Control Cover DabkOrnamental Grate Enhancer GA9320 Ornamental Grate Enhancer GA9330Vented Natural GAS Logs 901265 International Warranty Information