Desa VVSR18 Installing Damper Clamp, Connecting to GAS Supply, Checking GAS Connections

Page 8

®

VENTED NATURAL GAS LOGS

INSTALLATION

Continued

INSTALLING DAMPER

CLAMP

Secure the damper stop clamp provided to the leading edge of the damper as shown in Figure 5. If for any reason this clamp doesn't work on your fireplace, another suitable clamp or permanent stop must be installed, or the damper blade must be cut or removed.

Damper Clamp

Damper Damper

Masonry Fireplace

Manufactured

 

Fireplace

Damper

Clamp

Damper

Figure 5 - Attaching Damper Clamp

CONNECTING TO GAS SUPPLY

WARNING: A qualified ser- vice person must connect log set to gas supply. Follow all local codes.

Installation Items Needed

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to log set. If pipe is too small, undue loss of pressure will occur.

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from log set (see Figure 6).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in a clogged burner injector.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 6. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into log set controls. If sediment trap is not installed or is installed wrong, log set may not run properly.

Approved Flexible Gas Hose (if allowed by local codes)

A.G.A. Design-Certified

Manual Shutoff Valve

With 1/8" NPT Tap*

CHECKING GAS

CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG

1.Disconnect log set and its individual manual shutoff valve from gas supply piping system.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

3.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Reconnect log set and manual shutoff valve to gas supply. Check reconnected fittings for leaks.

Before installing log set, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to Propane/LP gas)

manual shutoff valve

test gauge connection

adjustable (crescent) wrench or pliers

sediment trap

tee joint

pipe wrench

3" Minimum

From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)

Cap Pipe Nipple Tee Joint

Sediment Trap

Figure 9 - Gas Connection

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 20.

**Minimum inlet pressure for purpose of input adjustment.

8

901265

Image 8
Contents For Use with Log Sets OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Safety Information Vented Natural GAS LogsProduct Identification Optional Product Features ON/OFF Safety VALVE/ Pilot KIT and PROPANE/LP ConversionRemote Control Ready Millivolt Safety VALVE/ Pilot KIT Remote Control AccessoriesAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Appliance Location Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Flue Opening SpecificationsVenting Specifications for Installation Check GAS TypeInstalling Damper Clamp Connecting to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemHearth KIT Assembly and Installation Optional GA9000 ON/OFF Safety VALVE/PILOT KIT AssemblyKit Assembly Installation and Gas ConnectionPropane/LP Gas Conversion Burner Inlet FittingTesting Burner for Leaks Installing the Grate and LogsAdding PAN Material Changing Pilot OrificeOperating Appliance Shutting Off Burner Only pilot stays lit TroubleshootingTo Turn OFF GAS To Appliance Clean pilot see Cleaning and Mainte Top Gas leak. See Warning statement atIllustrated Parts Breakdown VVSR18, VVSR24, VVDR18, VVDR24, and VVDR30Parts List VVSR18 VVSR24, VVDR18 VVDR24, and VVDR30LOG SET Models VSLR18, VSLR24, VDLCR18, VDLCR24, and VDLCR30 Parts List Accessories Cleaning and MaintenanceReplacement Parts Decorative ASH BED Control Cover Dabk Ornamental Grate Enhancer GA9310Ornamental Grate Enhancer GA9320 Ornamental Grate Enhancer GA9330Vented Natural GAS Logs 901265 Warranty Information International