Desa VSGF36PTA Blower Operation, Optional HAND-HELD Remote Operation, Shutting Off Heater

Page 22

OPERATING FIREPLACE

Continued

BLOWER OPERATION

WARNING: Make sure the se- lectorswitchisintheOFFposition whenyouareawayfromhomefor long periods of time. Heater will comeonautomaticallywithselec- tor switch in the ON position.

Pilot

Ignitor

Pilot

Ignitor

Burner

Electrode

Electrode

Burner

 

 

Figure 30 - Pilot

Figure 31 - Pilot

(Natural)

(Propane/LP)

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2a.

Set selector switch in the OFF position.

2b.

If Using Optional Hand-Held Remote: Set

 

selector switch in the OFF position to keep

 

from draining battery.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot

lit by doing one of the following:

Turn control knob clockwise to the PILOT position.

Use remote control manual OFF button.

Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 21.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions, page 21.

WARNING: This fireplace has athree-prong,groundedelectrical plug. This plug helps protect you againstelectricalshock.Onlycon- nect plug to a properly grounded, three-prongreceptacle.Donotcut or remove the grounding prong from this plug.

Locate the blower switch by opening lower louver on fireplace. Blower switch is located at lower left inside louver door. Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace. Note: Periodically check the louvers of the firebox and remove any dust, dirt or other obstructions.

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, pages 31). Follow instructions included with the re- mote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 21.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON posi- tion. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 32, page 23). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

22

www.desatech.com

116746-01A

Image 22
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes Product Identification Product FeaturesUnpacking Locating Firebox Product SpecificationsPlanning Unusually Tight Construction AIR for Combustion VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsInstallation Clearances Minimum Wall and Ceiling Clearances see FigureBUILT-IN Firebox Installation Mantel Clearances for Built-In InstallationRough Opening Dimensions for Built-in Installation Installing Firebox Using Optional Accessory Mantels Installing GAS Piping to Fireplace LocationNatural Gas Installation Items NeededPropane/LP Connecting Fireplace to GAS Supply Removing Log Base Assembly From FireplaceKPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaGroove HARD-WIRING Firebox Installing Fireplace Hood and ScreenOperating Fireplace Thermostat Models For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureRemote Control Models For Your Safety Read Before Lighting Thermostat Control OperationSet flame adjustment knob to any level between HI and LO Optional HAND-HELD Remote Operation Blower OperationShutting Off Heater ON/OFF Series Model HRC100 Thermostat Series Model HRC200Pilot Flame Pattern Key Pad Lock FeatureInspecting Burners Main BurnerCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleTechnical Service Wiring Diagram Replacement PartsSpecifications Service HintsTroubleshooting Observed Problem Possible Cause RemedyDiagram, See Cleaning and Mainte Shut off gas supply Do not try to light any appliance Accessories Illustrated Parts Breakdown Models VSGF36PTA, VSGF36NTAParts List Models VSGF36PRA, VSGF36NRA KEY Part Number VSGF36PRA VSGF36NRA Description QTY Models VSGF36PTA, VSGF36NTA, VSGF36PRA and VSGF36NRA KEY Part Number Description QTY 116746-01A 116746-01A Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace System

VSGF36NRA, VSGF36NTA, VSGF36PTA, VSGF36PRA specifications

Desa VSGF36PRA, VSGF36PTA, VSGF36NTA, and VSGF36NRA are various models from a contemporary line of gas fireplaces that combine aesthetics, functionality, and advanced technology to enhance residential spaces. Each model offers unique features and characteristics designed to meet different consumer needs and preferences.

The VSGF36PRA model stands out with its radiant heat and realistic flame display, effectively mimicking the experience of a traditional wood-burning fireplace. Its easy installation process makes it a viable choice for both new constructions and retrofitting existing spaces. The model utilizes high-efficiency gas burning technology, ensuring a warm and cozy environment while maintaining energy savings. Furthermore, it boasts a stylish design that can seamlessly integrate into any living room setting.

The VSGF36PTA is another dynamic addition to the lineup, featuring a traditional appearance with modern advancements. This model is known for its programmable thermostat that allows homeowners to control the temperature more precisely. The patented burner system creates a beautiful and lifelike flame, adding to the ambiance of any room. Additionally, the VSGF36PTA is equipped with a safety shut-off feature, ensuring peace of mind for users.

In contrast, the VSGF36NTA model targets those who appreciate a contemporary design. With its sleek lines and minimalistic facade, it offers an elegant touch to modern homes. This model incorporates advanced electronic ignition and a remote control for effortless operation, allowing users to enjoy their fireplace with convenience. The high-efficiency venting system also ensures optimal performance with lower emissions, making it environmentally friendly.

Lastly, the VSGF36NRA model combines both performance and versatility. This unit is designed for flexible installation options, allowing it to fit into various spaces. The customizable flame height and adjustable fan speed are key features that enhance the user experience. In terms of heating capabilities, the VSGF36NRA is engineered to provide reliable warmth during colder months while ensuring high efficiency.

Overall, the Desa VSGF36 series offers a diverse range of options suitable for various aesthetic preferences and functional needs. Each model features cutting-edge technology, ensuring that homeowners can enjoy the beauty and warmth of a fireplace while benefiting from enhanced efficiency and safety features.