NEC NDA-30016-003 manual MAT Assignments, Assignment of MSF Function Key

Page 21

Roamer Installation Guide

MAT Assignments

Chapter 4 MAT Assignments

This guide assumes that data settings that affect the operation of all OAI software on a system-wide basis have already been assigned on the NEAX Maintenance Administration Terminal (MAT). Such settings include system index values and assignment of Interface I/O Port Data in the Interface Processor (IP). For more information about these system data settings and the MAT commands described below, refer to the OAI Module Installation Manual for the NEAX2400 IMS, the NEAX2400 IMS Command Manual, the NEAX2400 IMS Job Specification Manual, and the NEAX2400 IMS Programming Manual.

Assignment of MSF Function Key

Roamer requires MAT assignment of the Mode Set Facility (MSF) to an OAI- assigned function key on all Dterms affected by application. This process involves assigning the MSF and its Operation Code (Op-Code), configured for Roamer in the APM Application Configuration option, to one of the 14 OAI Key Codes. (The MSF Op-Codes range from 128 to 191. These are available for on-screen viewing through the Providers command in the APM Application Configuration option.)

Each of the OAI Key Codes corresponds to an AKY1 Function Key Index (FKI) value which is then assigned to the specific Dterm function key. This process is

illustrated below:

 

 

PBX Correspondence of

 

 

 

 

AOKC

 

 

AKY1

 

 

 

 

OAI

 

Function

 

 

 

 

Key Codes

Key Indices

 

 

APM

MAT

1

< . . . .>

34

MAT

 

Application

AOKC

AKY1

 

2

< . . . .>

35

 

Configuration

Command

 

Command

 

 

 

 

 

 

 

 

3

< . . . .>

36

 

 

 

 

 

Designation of

Assignment of

4

< . . . .>

37

Assignment of

. . . . .

 

 

 

 

. .. .. .. .

Facility (Type)

an OAI Key Code

5

< . . . .>

38

Corresponding

. . .

and its Op-Code

(between 1 and 14)

6

< . . . .>

39

MAT Function

 

for Use by

to the Same

 

7

< . . . .>

40

Key Index to a

 

Roamer

Facility Type

 

specific Dterm

 

 

 

 

 

 

 

and Op-Code

8

< . . . .>

41

 

 

Function Key

 

 

 

9

< . . . .>

42

 

 

 

 

 

 

 

10

< . . . .>

43

 

 

 

 

11

< . . . .>

44

 

 

 

 

12

< . . . .>

45

 

 

 

 

13

< . . . .>

46

 

 

 

 

14

< . . . .>

47

 

 

Figure 4-1 OAI Function Key Assignment

A knowledge of the Dterm stations in the NEAX system and which ones will have access to Roamer is necessary to making the following assignments:

NDA-30016 Revision 3.0

Page 15

Image 21
Contents Roamer Liability Disclaimer Table of Contents This Page Left Blank List of Figures Figures Introduction ChapterIntroduction Roamer Installation Guide Installation Requirements This Page Left Blank Application Characteristics Application ConfigurationPrimary Configuration Parameters OAI Facilities Database Requirements on Secondary OAI Configuration ParametersAssignments on User-Defined ParametersNDA-30016 Revision Roamer Database Database RequirementsSFC InstructionsField Definitions This Page Left Blank Assignment of MSF Function Key MAT AssignmentsAKY1 Command Assignment of Dterm Function Key Aokc Command Assignment of OAI Key CodesAsyd Command Assignment of System Data Assignment of Free Location FeatureMAT Assignments Roamer Installation Guide