EMERGENCIES: If a gas leak cannot be stopped, or a fire occurs due to gas leakage, call the fire department.

Emergencies

Possible Cause

Prevention/Solution

 

 

 

Gas leaking from

• Damaged hose.

• Turn off gas at LP cylinder or at source on natural gas systems. If the

cracked/cut/burned

 

hose is cracked or cut but not burned, simply replace valve/hose/

hose.

 

regulator. If the hose is burned, the cause could be other than a faulty

 

 

valve/hose/regulator. Discontinue use of grill until a plumber or gas

 

 

technician has investigated and corrected the problem.

Gas leaking from LP

• Mechanical failure due to rusting or

• Replace LP cylinder.

cylinder.

mishandling.

 

Gas leaking from LP

• Failure of cylinder valve from

• Turn off LP cylinder valve. Return LP cylinder to gas supplier.

cylinder valve.

mishandling or mechanical failure.

 

Gas leaking between

• Improper installation, connection not

• Turn off LP cylinder valve. Remove regulator from cylinder and

LP cylinder and

tight, failure of rubber seal.

visually inspect rubber seal for damage. See LP Cylinder Leak Test

regulator connection.

 

and Connecting Regulator to the LP Cylinder.

Fire coming through

• Fire in burner tube section of burner due

• Turn off control knobs and LP cylinder valve. Leave lid open to allow

control panel.

to blockage.

flames to die down. After fire is out and grill is cold, remove burner

 

 

and inspect for spider nests or rust. See Spider Alert and Cleaning the

 

 

Burner Assembly sections of this Use & Care Guide.

Grease fire or

• Too much grease buildup in burner area.

• Turn off control knobs and LP cylinder valve. Leave lid open to

continuous excessive

 

allow flames to die down. After cooling, clean food particles and

flames above cooking

 

excess grease from inside firebox area, grease tray, and other

surface.

 

surfaces.

Troubleshooting

Problem

Burner(s) will not light using ignitor.

(See Electronic Ignition Troubleshooting also)

Continued on next page.

Possible Cause

GAS ISSUES:

Trying to light wrong burner.

Burner not engaged with control valve.

Obstruction in burner.

No gas flow.

Vapor lock at coupling nut to LP cylinder.

Coupling nut and LP cylinder valve not fully connected.

ELECTRICAL ISSUES:

Electrode cracked or broken; “sparks at crack.”

Electrode tip not in proper position.

Wire and/or electrode covered with cooking residue.

Wires are loose or disconnected.

Wires are shorting (sparking) between ignitor and electrode.

Prevention/Solution

See instructions on control panel and in Use and Care section.

Make sure valves are positioned inside of burner tubes.

Ensure burner tubes are not obstructed with spider webs or other matter. See cleaning section of Use and Care.

Make sure LP cylinder is not empty. If LP cylinder is not empty, refer to “Sudden drop in gas flow.”

Turn off knobs and disconnect coupling nut from LP cylinder. Reconnect and retry.

Turn the coupling nut approximately one-half to three-quarters additional turn until solid stop. Tighten by hand only - do not use tools.

Replace electrode(s).

Main Burners:

Tip of electrode should be pointing toward gas port opening on burner. The distance should be 1/8” to 1/4”. Adjust if necessary.

Sideburner:

Tip of electrode should be pointing toward gas port opening on burner. the distance should be 1/8” to 3/16”. Adjust if necessary.

Clean wire and/or electrode with rubbing alcohol and clean swab.

Reconnect wires or replace electrode/wire assembly.

Replace ignitor wire/electrode assembly.

• Dead battery.

• Replace with a new AA-size alkaline battery.

464220110 • 23

Image 23
Contents Grill Information Center Sears Model No Safety Parts Use and Care AssemblyTools needed for assembly Product Record Installation Safety PrecautionsSafety Symbols Call Grill Information Center for Help and PartsWarranty Only LP Tanks equipped with this type of valve LP Tank Valve Safety Cap Retainer StrapLP Liquefied Petroleum Gas LP Tank FillingLP Tank Leak Test Connecting Regulator To The LP TankFor your safety LP Tank ExchangeNever remove threaded orifice at end of valve Leak Testing Valves, Hose and RegulatorTurn all grill control knobs to OFF Open lid during lighting For Safe Use of Your Grill and to Avoid Serious InjuryIgnitor Lighting the Grill SDo not lean over grill while lightingBurner Flame Check General Grill CleaningSideburner Ignitor Lighting Sideburner Match LightingTurn gas OFF at control knobs and LP cylinder Cleaning the Burner AssemblyStoring Your Grill Very Important Burner tubes must reengage valveIndirect Cooking Instructions Food SafetyHow To Tell If Meat Is Grilled Thoroughly Burner CookingParts List Parts Diagram Bottom Shelf to Legs RearFront Panel Tank Exclusion WireCone side of wheel against leg Wheels and Leg Extenders to Cart20x1/2 screws Grill Head to CartFascia, Right Side Shelf Right Side ShelfLeft Fascia Lid removed for claritySide Burner Shelf Correctly assembled burner-to-valve engagement Ignitor wireHeat Shield Cooking Grate and Swing Away Heat DiffusersLP Tank Grease Cup Clip, Grease Cup, Grease TrayEmergencies Possible Cause Prevention/Solution TroubleshootingElectronic Ignition Section Troubleshooting Electronic IgnitionPage 464220110 MY-HOME1-800-469-4663 Sears Parts & Repair Service CenterNo matter who made it, no matter who sold it SU-HOGAR