Lighting the SEAR ZONE Infrared Burner (if applicable) |
| |
1. Open Sear Zone Side burner lid. Ensure all control knobs in the OFF position |
| |
before opening the gas supply. |
| |
2. Turn on the gas supply valve at the tank (1 to 2 turns) or turn on the main gas |
| |
supply valve. |
| |
3. Turn the Sear Zone burner control knob to the SEAR/ “HI” position. |
| |
4. Press and hold ELECTRONIC IGNITER button. |
| |
5. If the Sear Zone does NOT light, turn knob to OFF, turn off LP or NG gas, wait |
| |
5 minutes, and then repeat lighting procedure. | Centro 6800 only. | |
6. If the Sear Zone burner still does not light follow the match lighting procedure for the Sear Zone. | ||
|
WARNING
With models with Sear Zone infrared burner included in main cooking area, never operate main BBQ burners in conjunction with Sear Zone infrared burner unless BBQ lid is left open. Using the Sear Zone main burners with the BBQ lid closed may result in overheating your BBQ, fire, explosion, personal injury or property damage.
Match lighting the Sear Zone Infrared burner (if applicable)
1.Open lid Sear Zone side burner lid. Ensure all Control knobs are in the OFF position before opening the gas supply.
2.Turn on the gas supply valve at the tank (1 to 2 turns) or turn on the main gas supply valve.
3.Place a lit match or a butane lighter directly beside the Sear Zone electrode.
4.Turn the Sear Zone control knob to the SEAR/“HI” position. Be sure the burner lights and stays lit.
ATTENTION
Always preheat barbecue before starting to cook. Light all burners and adjust them to the HIGH position for 5 to 10 minutes with the lid closed. Following preheat; adjust the controls to medium setting for most cooking requirements.
Turning Grill Off
1.Turn all knobs to OFF position.
2.Turn LP cylinder off by turning
WARNING
If the heat output is too low, the flow control feature may have been activated by a gas leak or improper lighting procedure. If so, turn off the burner valve and cylinder valve, and perform a“Leak Test”. If there are no leaks, perform a complete regulator flow limiting device reset.
Valve Check
Important: Make sure gas is off at LP cylinder before checking valves. Knobs lock inOFF position. To check valves, first push in knobs and release, knobs should spring back. If knobs do not spring back, replace valve assembly before using grill. Turn knobs to LOW position then turn back to OFF position. Valves should turn smoothly.
VERY IMPORTANT: Burner tubes must engage valve space openings.
See illustration at right.
1.Attach electrode to burner.
2.Carefully replace burners.
3.Attach burners to brackets on firebox.
4.Reposition carryover tubes and attach to burners.
Replace flame tamers and cooking grates.
Ensure burner sits properly over valve.
8