Centro 03122008 EJ warranty Natural GAS HOOK-UPS and Warnings, Operation Lighting Instructions

Page 9

NATURAL GAS HOOK-UPS AND WARNINGS

NEW Natural Gas Barbecue

If you are experiencing poor natural gas barbecue performance, including but not limited to low flame, low heat or poor heat distribution, please review the following information:

Always consult the Rating Label on the back of the barbecue to confirm that it has already been configured to burn natural gas.

If experiencing performance issues with a brand new barbecue hooked up to an older natural gas home connection, it is possible that the natural gas supply line is not able to supply up to the essential 85,000 BTU’s required (depending on the

model). Please contact Centro Customer Care for requirements and then consult with your certified natural gas technician.

All gas supply plumbing must be carried out by a qualified service agency. The Supply connection shall be carried out in accordance with provincial authorities having jurisdiction, and in accordance with CAN/CGA 1-B149.1 & 2 installation code requirements.

A shut off valve must be installed between the barbecue and the main supply. For natural gas, use a 3/8” or 1/2” natural gas supply line capable of an input of up to 85,000 BTU’s (depending on the model).

When conducting pressure test always isolate the barbecue from the gas supply piping system by disconnecting the barbecue and closing its individual manual shutoff valve. The gas supply piping system should be tested at pressures which exceed 1/2 psi (3.5kPa).

All gas supply plumbing must be able to supply 7” water column to the barbecue WITH ALL BURNERS IN OPERATION.

WARNING

ALL Centro BBQ’s are sold either NATURAL GAS or PROPANE READY and are not convertible from one gas source to another.

OPERATION — LIGHTING INSTRUCTIONS

Lighting the Main Burners:

1.Open lid and inspect the barbecue and burners to confirm that all components are properly positioned before lighting the main burners.

2.Always confirm that all burner control knobs are in the OFF position before opening the gas supply.

3.Turn on the gas supply valve at the tank (1 to 2 turns) or turn on the main natural gas supply valve.

4.Turn the selected burner control knob to the HIGH position by pushing in and turning the knob counter clockwise.

5.Immediately activate the Igniter. The selected burner should light within five seconds. Light the burners sequentially from either left to right or right to left.

6.If ignition does NOT occur in 5 seconds, turn the burner controls OFF, wait 5 minutes for the gas to clear and repeat the lighting procedure.

7.If the burner will not light when using the ignitor, follow the match lighting instructions.

WARNING

Never stand with your head directly over the barbecue when preparing to light the main burners, to prevent possible bodily injury.

ATTENTION

Once lit, confirm that the burner is properly lit and that the flame pattern is as desired. If the flame pattern is other than normal, consult the troubleshooting guide for corrective action.

Burner Flame Check

Remove cooking grates. Light burners and rotate control knobs from HI to LOW. You should see a smaller flame in LOW position than seen on HI. Perform burner flame check on all burners. Also, always check flame prior to each use.

Turning Grill Off

Turn all knobs to OFF position. Turn LP cylinder off by turning hand-wheel clockwise to a full stop.

Ignitor Check

Turn gas off at LP cylinder.Press and hold electronic ignitor button. “Click”should be heard and spark seen each time between burner and electrode.

Hose Check

Before each use, check to see if hoses are cut or worn. Replace damaged hoses before using grill. Use only valve/hose/regulator specified by manufacturer.

6

Image 9
Contents For your family’s safety, please check the following WarrantySafety & Care Manual Table of Contents Additional Warnings InstallationGAS Cylinder Requirements Minimum clearance to adjacent combustible materialsLP Liquid Petroleum GAS GAS HOOK-UP’S and WarningsLP cylinder requirements LP cylinder valve must have Cylinder REMOVAL, Transport and Storage Before disconnecting the LP cylinder Cylinder Filling LP GAS WarningsLP Cylinder Leak Test For Your Safety Safety Hose and RegulatorConnecting Regulator to the LP Cylinder Hose and Regulator comes equipped with the followingTo Connect Leak Testing the VALVE, Hose and Regulator AssemblyTo Disconnect Turn all grill control knobs to OFFOperation Lighting Instructions Natural GAS HOOK-UPS and WarningsLighting the Side Burner if applicable Match-Lighting Main BurnersLighting the Sear Zone Infrared Burner if applicable Grilling Tips Cooking and PerformanceGeneral Side Burner Tips General Infrared Rotisserie Burner TipsD. BBQ Lights General Sear Zone Infrared Side Burner TipsGrease Fires Flash FiresFor Your Safety TroubleshootingResolving Igniter Performance Issues Problem Cause Corrective ActionIng the various electrode wires Confirm that the lead wire, fromBattery cap not threaded properly Ensure proper burner installationProblem Identifying the Cause Resolving Burner Performance IssuesCleaning and Maintenance Cleaning and Maintenance of the Sear Zone Burner How to season Porcelain Cast iron cooking gratesWash cooking grates with soap and water Cleaning Stainless steel Surfaces Cleaning Stainless Steel partsStoring Your BBQ BBQ to protect it from premature corrosionWarranty and Service Limited WarrantyIf Your Product is Damaged Limitation and Exclusions