Char-Broil 466247310 Leak Testing Valves, Hose and Regulator, Turn all grill control knobs to OFF

Page 6

Hold coupling nut and regulator as shown for proper connection to LP cylinder valve.

6.Turn the coupling nut clockwise and tighten to a full stop. The regulator will seal on the back-check feature in the LP cylinder valve, resulting in some resistance. An additional one-half to three-quarters turn is required to complete the connection. Tighten by hand only – do not use tools.

NOTE:

If you cannot complete the connection, disconnect regulator and repeat steps 5 and 6. If you are still unable to complete the

connection, do not use this regulator!

DANGER

Do not insert any tool or foreign object into the valve outlet or safety relief valve. You may damage the valve and cause a leak. Leaking propane may result in explosion, fire, severe personal injury, or death.

WARNING

Outdoor gas appliance is not intended to be installed in or on a boat.

Outdoor gas appliance is not intended to be installed in or on an RV.

Never attempt to attach this grill to the self-contained LP gas system of a camper trailer or motor home.

Do not use grill until leak-tested.

If a leak is detected at any time, STOP and call the fire department.

If you cannot stop a gas leak, immediately close LPcylinder valve and call LP gas supplier or your fire department!

6

Leak Testing Valves, Hose and Regulator

1.Turn all grill control knobs to OFF.

2.Be sure regulator is tightly connected to LP cylinder.

3.Completely open LP cylinder valve by turning hand wheel counterclockwise. If you hear a rushing sound, turn gas off immediately. There is a major leak at the connection. Correct before proceeding.

4.Brush soapy solution onto areas circled below, or other similar fittings on your grill.

 

 

 

 

 

 

 

 

NOTE: Your grill

 

 

NOTE: Sideburner

 

may NOT be

 

 

shelf fascia not

 

equipped with a

 

 

shown for clarity.

 

sideburner.

 

 

 

 

 

 

5.If “growing” bubbles appear, there is a leak. Close LP cylinder valve immediately and retighten connections. If leaks cannot be stopped do not try to repair. Call for replacement parts.

6.Always close LP cylinder valve after performing leak test by turning hand wheel clockwise.

Image 6
Contents Estimated assembly time 30 minutes Date PurchasedTable of Contents This Grill is for Outdoor USE onlyInstallation Safety Precautions California PropositionLP Cylinder Filling USE and CareLP Liquefied Petroleum Gas UL listed Overfill ProtectionFor your safety UseDo not household cleaning agents. Damage to gasLP Cylinder Leak Test Leak Testing Valves, Hose and Regulator Connection, do not use this regulatorTurn all grill control knobs to OFF For Safe Use of Your Grill and to Avoid Serious Injury Main Burner Lighting InstructionsBurner Flame Check Side Burner Lighting InstructionsSideburner Match Lighting Ignitor CheckStoring Your Grill General Grill CleaningCooking surfaces If a bristle brush is used to clean any SurfacesCleaning the Burner Assembly Turn gas off at control knobs and LP cylinderLimited Warranty Items Manufacturer will not PAY forParts List Not PicturedKey Qty Description Parts Diagram Fixed caster Locking caster AssemblyFront Bottom shelf RearGrill head Regulator hose Lower back panel Rear of Shelf Screws and Washers removed from valve bracket Now you may fully tighten lower screws on upper back panel Front of ShelfBack of main control panel Holes on fascia to Sideburner lid Front brace Page Wire Frontbrace Right door Cooking grate Cylinder screw at rear of cart Troubleshooting Emergencies Possible Cause Prevention/SolutionAUTO-CLEAN Troubleshooting Electronic Ignition SectionWarranty Registration Department Box Columbus, GA