Char-Broil 466247310 Side Burner Lighting Instructions, Sideburner Match Lighting, Ignitor Check

Page 8

WARNING

Turn controls and gas source or tank OFF when not in use.

CAUTION

If ignition does NOT occur in 5 seconds, turn the burner controls OFF, wait 5 minutes and repeat the lighting procedure. If the burner does not ignite with the valve open, gas will continue to flow out of the burner and could accidently ignite with risk of injury.

Match-Lighting

sDo not lean over grill while lighting.

1.Turn OFF all burner control valves.

2.Turn ON gas at LP cylinder.

3.Open lid during lighting.

4.Push in and turn AUTO-CLEANvalve to GRILL position.

5.Place match into match holder (hanging from side panel of grill). Light match; then light burner by placing match through the match light hole on right or left side of grill.

6.Push in and turn far right or far left burner knob to the position, depending on match light hole selected. Be sure burner lights and stays lit.

7.Light adjacent burners in sequence by pushing knobs in and

turning to the position.

Side Burner Lighting Instructions:

sDo not lean over grill while lighting.

1.Turn OFF all gas burner control valves.

2.Turn ON gas source or tank.

3.Open lid during lighting.

4.Push in and turn AUTO-CLEANvalve to GRILL position.

5.To ignite SIDEBURNER, turn sideburner knob to the position.

6.Push and hold the ELECTRONIC IGNITOR button untill the sideburner lights.

7.Once burner has ignited, turn knob to desired setting.

8.If ignition does not occur in 5 seconds, turn the burner control

to OFF, wait 5 minutes, and repeat the lighting procedure.

Sideburner Match Lighting

1.Turn OFF all burner control valves.

2.Open sideburner lid. Turn on gas at LP cylinder.

3.Place lit match near burner.

4. Turn sideburner knob to

HIGH . Be sure burner lights and stays lit.

Burner Flame Check

Remove cooking grates and flame tamers. Light burners, rotate knobs from HI to LOW. You should see a smaller flame in LOW position than seen on HI. Perform burner flame check on sideburner, also. Always check flame prior to each use. If only low flame is seen refer to "Sudden drop or low flame" in the Troubleshooting Section.

HI

LOW

Turning the Grill OFF with AUTO-CLEAN™

With the Autoclean feature you have two choices for turning off your grill; Manual and AUTO-CLEAN™

Manual Method

Turn all knobs, including the AUTO-CLEAN™ valve, to the OFF position.

Turn OFF the LP cylinder by turning the handwheel clockwise to a full stop.

NOTE: Always follow the lighting instructions found in the instruction manual and also located on the inside of the cabinet door prior to using the Auto-Clean feature. Grill must be ignited prior to using the Auto-Clean feature.

AUTO-CLEAN™ Method

After cooking is complete, set all main burner grill knobs to the high setting and close the grill lid. (AUTO-CLEAN™ shutdown should not be used on the sideburner.)

Push in and turn the AUTO-CLEAN™ knob to the clean position.

Once at the clean position, release the knob and the green light should begin blinking.

The valve will now stay on for 15 minutes before turning off the gas to the burners.

After the clean cycle is complete, turn all knobs including the AUTO-CLEAN™ valve to the OFF position.

Turn OFF the LP cylinder by turning the handwheel clockwise to

a full stop.

For safety in storing a grill, the LP cylinder should always be turned

OFF

If red light comes on while green light is flashing, the batteries will need to be replaced very soon.

When changing the batteries, please replace both batteries at the same time. Always replace with new batteries of the same type.

Ignitor Check

Turn gas off at LP cylinder. Press and hold electronic ignitor button. "Click" should be heard and spark seen each time between each collector box or burner and electrode. See "Troubleshooting" if no click or spark.

Valve Check

Important: Make sure gas is off at LP cylinder before checking valves. Knobs lock in OFF position. To check valves, first push in knobs and release, knobs should spring back. If knobs do not spring back, replace valve assembly before using grill. Turn knobs to LOW position then turn back to OFF position. Valves should turn smoothly.

Hose Check

Before each use, check to see if hoses are cut or worn. Replace damaged hoses before using grill. Use only valve/hose/regulator specified by manufacturer.

8

Image 8
Contents Estimated assembly time 30 minutes Date PurchasedTable of Contents This Grill is for Outdoor USE onlyInstallation Safety Precautions California PropositionUSE and Care LP Liquefied Petroleum GasLP Cylinder Filling UL listed Overfill ProtectionLP Cylinder Leak Test For your safetyUseDo not household cleaning agents. Damage to gas Turn all grill control knobs to OFF Leak Testing Valves, Hose and RegulatorConnection, do not use this regulator For Safe Use of Your Grill and to Avoid Serious Injury Main Burner Lighting InstructionsSide Burner Lighting Instructions Sideburner Match LightingBurner Flame Check Ignitor CheckGeneral Grill Cleaning Cooking surfaces If a bristle brush is used to clean anyStoring Your Grill SurfacesCleaning the Burner Assembly Turn gas off at control knobs and LP cylinderLimited Warranty Items Manufacturer will not PAY forKey Qty Description Parts ListNot Pictured Parts Diagram Assembly FrontFixed caster Locking caster Bottom shelf RearGrill head Regulator hose Lower back panel Rear of Shelf Screws and Washers removed from valve bracket Back of main control panel Now you may fully tighten lower screws on upper back panelFront of Shelf Holes on fascia to Sideburner lid Front brace Page Wire Frontbrace Right door Cooking grate Cylinder screw at rear of cart Troubleshooting Emergencies Possible Cause Prevention/SolutionAUTO-CLEAN Troubleshooting Electronic Ignition SectionWarranty Registration Department Box Columbus, GA