Char-Broil 463222209 Leak Testing Valves, Hose and Regulator, Turn all grill control knobs to OFF

Page 6

Hold coupling nut and regulator as shown for proper connection to LP cylinder valve.

6.Turn the coupling nut clockwise and tighten to a full stop. The regulator will seal on the back-check feature in the LP cylinder valve, resulting in some resistance. An additional one-half to three-quarters turn is required to complete the connection. Tighten by hand only – do not use tools.

NOTE:

If you cannot complete the connection, disconnect regulator and repeat steps 5 and 6. If you are still unable to complete the

connection, do not use this regulator!

DANGER

Do not insert any tool or foreign object into the valve outlet or safety relief valve. You may damage the valve and cause a leak. Leaking propane may result in explosion, fire, severe personal injury, or death.

WARNING

Outdoor gas appliance is not intended to be installed in or on a boat.

Outdoor gas appliance is not intended to be installed in or on an RV.

Never attempt to attach this grill to the self-contained LP gas system of a camper trailer or motor home.

Do not use grill until leak-tested.

If a leak is detected at any time, STOP and call the fire department.

If you cannot stop a gas leak, immediately close LPcylinder valve and call LP gas supplier or your fire department!

6

Leak Testing Valves, Hose and Regulator

1.Turn all grill control knobs to OFF.

2.Be sure regulator is tightly connected to LP cylinder.

3.Completely open LP cylinder valve by turning hand wheel counterclockwise. If you hear a rushing sound, turn gas off immediately. There is a major leak at the connection. Correct before proceeding.

4.Brush soapy solution onto areas circled below, or other similar fittings on your grill.

 

 

 

 

 

 

 

 

NOTE: Your grill

 

 

NOTE: Sideburner

 

may NOT be

 

 

shelf fascia not

 

equipped with a

 

 

shown for clarity.

 

sideburner.

 

 

 

 

 

 

5.If “growing” bubbles appear, there is a leak. Close LP cylinder valve immediately and retighten connections. If leaks

cannot be stopped do not try to repair. Call for replacement

parts.

6.Always close LP cylinder valve after performing leak test by turning hand wheel clockwise.

Image 6
Contents Estimated assembly time 30 minutes Product GuideINSTALLER/ASSEMBLER Installation Safety Precautions California PropositionLP Liquefied Petroleum Gas LP Cylinder FillingLP Cylinder Exchange Connecting Regulator to the LP Cylinder LP Cylinder Leak TestLeak Testing Valves, Hose and Regulator Turn all grill control knobs to OFFFor Safe Use of Your Grill and to Avoid Serious Injury Main Burner Ignitor LightingTurning Grill Off Sideburner Match LightingBurner Flame Check Ignitor CheckGeneral Grill Cleaning Cleaning the Burner AssemblyStoring Your Grill Correct Engagement Reinstall Screws Grill Halogen Light Cleaning the Lens Limited Warranty Parts List Not PicturedParts Diagram Assembly RearSide of cart Control Panel Front Brace Inside of left side shelf Debris collecter Panel Upper back panelHoles on fascia to Sideburner grate #8x3/8 self-tapping screw Qty Heat shield Qty Clarity of illustration Emitter PlatesRear of grate Cooking grate Cylinder screw at rear of cart Troubleshooting Emergencies Possible Cause Prevention/SolutionAUTO-CLEAN Troubleshooting Electronic Ignition SectionPage Page Page Warranty Registration Department Box Columbus, GA