DCS BGB30-BQR manual Using the Rotisserie, Recommended, Working Area, Meat Preparation

Page 20

USING THE ROTISSERIE

IMPORTANT:

Never have the grill burners (bottom burners) on during Rotisserie cooking. It will burn your meat and make it very dry. Use only one thing on at a time, grill or rotisserie.

PREPARATION

Recommended:

Dental floss or butcher string, scissors, broiler pan (bottom only), pliers, instant read thermometer, foil, and hot pads.

Working Area:

 

Allow enough space to accommodate food and

 

rotisserie rod assembly in a clean environment.

 

Meat Preparation:

 

Tie meat with butcher string or Dental floss in

 

three areas. Buy a roast that is equally balanced

 

from top to bottom in size. The meat will cook

 

more evenly while on the Rotisserie. For Poultry,

 

tie wings and legs to the body using Dental floss

 

or butcher string to prevent flopping around

 

while turning. (Fig. 24)

FIG. 24

1.Determine the center placement for the food, put 1st prong on Rod, turn L shape screw to tighten.

2.Center tied meat/poultry on Rod, place second prong, turn L shape screw to tighten. (Fig. 25)

3.Pick up Rod, rotate it to check for balance. If not, adjust prongs and food to balance. Take pliers and tighten the L shape screw on both sides of the prong.

4.Remove grates and top rack on the grill, place bottom portion of broiler pan on ceramic rods, so meat drippings can be caught in pan. (Fig. 26)

FIG. 25

FIG. 26

19

Image 20
Contents Professional 30 BGB Grill Message to OUR Customers Please Retain this Manual for Future ReferenceTable of Contents Safety Practices & Precautions Important Safety NoticeGrill Placement Safety Practices & Precautions Grill Models To HOOK-UP the Fittings Supplied with the Grill GAS RequirementsTotal GAS Consumption of the Grill with ALL Burners on HI LP GAS Hook UP Type 1 or QCC1 Regulator LP Tank RequirementsLocating GRILL/BUILT-IN Clearances Insulated JacketLocation Clearances to Non-Combustible ConstructionGeneral Ventilation RequirementsBUILT-IN Construction Details Standard layout for non-combustible enclosureTo Test Leak TestingBefore Testing Grill Burner Flame Height Installer CHECKLIST/BURNER AdjustmentsInstaller Final Checklist Grill Burner Adjustments Grill Burner Air AdjustmentTo Adjust LOW Setting AdjustmentsGrill Using the GrillRadiant Asssembly Installation Grilling Hints Replacement of Regulators and HoseImportant Using the Grill Match Lighting Using the GRILL/LIGHTING InstructionsTo Light the Grill Burner ROD Light Motor Using the Rotisserie PreparationRecommended Working AreaCooking on Rotisserie To Light the Rotisserie Burner Manual LightingCare and Cleaning Grill Burner Burner Removal and CleaningGrill burner cleaning Troubleshooting Before Calling for ServiceGrill won’t light when the ignition button is pushed Low heat with knob in HI positionGrill Burner Assembly TEMGrill Body Parts List Rotisserie Assembly Grill Cart Parts List Cart Assembly Instructions Tools Required not includedBefore Assembling the Cart Remove packagingGrill placement onto cart Final assemblyGas hookup LP hookup Side tray adjustmentSide shelf adjustment Wiring Diagram BGB30-BQR Models Wiring DiagramService HOW to Obtain ServiceWarranty Length of WarrantyDCS Will Pay For DCS Will Not Pay ForPage Page Litho in USA 09/2001

BGB30-BQR specifications

The DCS BGB30-BQR is a state-of-the-art gas monitoring and detection system, designed to ensure maximum safety and reliability in a variety of industrial environments. This advanced device integrates cutting-edge technologies and sophisticated features that make it a preferred choice for professionals in sectors such as oil and gas, manufacturing, and chemical processing.

At the heart of the BGB30-BQR lies its high-performance gas sensors, which are capable of detecting a wide range of hazardous gases including methane, propane, and hydrogen sulfide. These sensors utilize advanced electrochemical technology that allows for quick and accurate readings, ensuring that any potential gas leaks can be identified rapidly. The device is designed for real-time monitoring, providing continuous data to maintain safety in critical settings.

One of the standout features of the BGB30-BQR is its robust wireless communication capabilities. Equipped with built-in Bluetooth and Wi-Fi, the system allows for seamless integration into existing network infrastructures. This feature enables operators to access real-time data remotely via smartphones or tablets, empowering them to make informed decisions instantly. Additionally, the BGB30-BQR supports both local and cloud-based data storage, ensuring that historical data is available for analysis and regulatory compliance.

The BGB30-BQR is also built with durability in mind. Its rugged design meets tough environmental standards, making it suitable for both indoor and outdoor applications. With an IP68 rating, the device is resistant to dust and water ingress, ensuring longevity in challenging conditions.

Another significant characteristic of the BGB30-BQR is its user-friendly interface. The device comes with an intuitive LCD display that shows real-time gas level readings, battery status, and alerts for immediate troubleshooting. Furthermore, the device includes customizable alarm settings that can be tailored to suit specific operational requirements, ensuring prompt responses to any sign of danger.

In conclusion, the DCS BGB30-BQR gas monitoring system exemplifies innovation in safety technology. With its advanced sensing capabilities, robust communication features, durable construction, and user-friendly design, it stands out as a reliable solution for gas detection in various industrial applications. Investing in the BGB30-BQR not only enhances workplace safety but also boosts operational efficiency by providing critical data when it matters most.