Kenmore 122.1613411 manual Checking for LP gas leaks, Grill Lighting Instructions for Main Burners

Page 16

Checking for LP gas leaks

Never test for leaks with a flame. Prior to first use, at the beginning of each season, or every time your LP gas tank is changed, you must check for gas leaks.

1.Make a 50/50 (soap/water) mild soap solution.

2.Turn the control knobs to full OFF position; then turn gas ON at supply tank.

3.Apply the soap solution with a clean brush to all gas connections. See below. If growing bubbles appear in the solution the connections are not properly sealed. Check each fitting and tighten or repair as necessary.

Gas Connection Leak Check

4.If you have a gas connection leak you cannot repair, turn gas OFF at supply tank, disconnect fuel line from your grill and call 1-800-913-8999 or your gas supplier for repair assistance.

5.Also apply soapy solution to the tank seams. See below. If growing bubbles appear, shut tank OFF and do not use or move it! Contact an LP gas supplier or your fire department for assistance.

Gas Tank Leak Check

Grill Lighting Instructions for Main Burners

1.Do not smoke while lighting grill or checking gas supply connections.

2.Be sure that LP gas tank is sufficiently full.

Z_ WARNING

Failure to open grill lid during the lighting procedure could result in a fire or explosion that could cause serious bodily injury, death, or property damage.

3.Be sure all gas connections are securely tightened.

4.Turn on gas supply.

5.Open the grill main lid.

6.Push and turn any main burner control knob to

HI,position. Push Electronic Ignition button for 3 to 5 seconds to light burner.

7.If the burner does not light after 5 seconds, turn knob to OFF. Turn gas OFF at LP tank and wait 5 minutes for gas to clear. Then turn gas ON at tank and repeat step 5

8.If burner still does not light, see Match Lighting section and If Grill Still Fails to Light section on following page.

9.To light additional burners, turn burner knob(s) to HI_ Push and hold electronic ignition button to ligl_t burner. Adjust knob(s) to desired setting.

USING THE SIDE BURNER:

Inspect the gas supply hose prior to turning the gas "ON". If there is evidence of cuts, wear or abrasion, it must be replaced prior to use. Do not use the side burner if the odor of gas is present.

WARNING: Always keep your face and body as far away from the burner as possible when

lighting.

LIGHTING INSTRUCTIONS FOR SIDE BURNER

1.Open side burner lid fully.

2.Push and turn side burner knob to _HI position. Push and hold Electronic Ignition button for 3-5 seconds to light burner.

3.If the side burner does not light after 5 seconds, turn knob to OFF. Turn gas OFF at LP tank and wait 5 minutes for gas to clear. Then turn gas ON at tank and repeat step 2.

4.If burner still does not light, see Match Lighting section and If Grill Still Fails to Light Section on following page.

16

Image 16
Contents Kenmoreo Grill Installation Codes Sears Brands Management Corporation, Hoffman Estates, ILProper Placement and Clearance of Grill IiiiiiRepair Protection Agreements Side Panel, Left 1pc Side Panel, Right Back panel Page Flat Head Screw 8mm Pcs Flat Washer @ .@ KEY# Parts Description Quantity JkY r Firebox Assembly Side Burner & Side Shelf Assembly Side Burner Valve Assembly B1. Use the two previously removed side burnerInstalling Cooking Components Grease Cup AssemblyBattery Assembly Connecting LP Gas Tank to LP Grill CongratulationsChecking for LP gas leaks Grill Lighting Instructions for Main BurnersManually Lighting Your Grill by Match Cleaning Exterior Stainless Steel Surfaces Annual Cleaning of Grill InteriorCleaning Burner Tubes and Burner Ports Jt,,e- II =1=v Vlvj-pII/,11lie ImleCooking Temperatures Direct CookingIndirect Cooking Flare-upsUSDA* Safe Minimum Internal Temperatures Fish Temperature TimeMY-HOME