Kenmore 122.1613411 manual Jt,,e- II =1=v, Vlvj-pII/,11lie Imle

Page 19

/_ WARNING

The location of the burner tube with respect to the orifice is vital for safe operation. Check to ensure the orifice is inside the burner tube before using the gas grill. If the burner tube does not fit over the valve orifice, lighting the burner may cause explosion and/or fire.

Regardless of which burner cleaning procedure you use, we recommend you also complete the following steps to help prolong burner life.

1.Use a fiber pad or nylon brush to clean the entire outer surface of each burner until free of food residue

and dirt.

BEFORE CALLING FOR SERVICE

2.Clean any clogged ports with a stiff wire, such as an open paper clip.

3.Inspect each burner for damage (cracks or holes) and if such damage is found, order and install a new burner. After installation check to ensure that gas

valve orifices are correctly placed inside the ends of the burner tubes.

/_ WARNING

Spiders and insects can nest inside the burners of the grill and disrupt gas flow. This very dangerous condition could cause a fire behind the valve panel, thereby damaging the grill and making it unsafe for operation. Inspect the grill at least twice a year.

If the grill does not function properly, use the following check list before calling for service.

You should inspect the burners at least once a year or immediately after any of the following conditions occur:

I-Jt,,[e]-] II =1=v[,:-]

Grill won't light when the control knob is rotated.

Burner flame is yellow or orange, in

combination with the odor of gas.

Low heat with knob in "HI" position.

I,vlvj-"p'II/,11lie] Imle]

Check to see if LP tank is empty.

Clean wires and/or electrode by rubbing with alcohol and clean swab.

Wipe with dry cloth.

Make sure the wire is connected to

electrode assembly.

Do other burners on the unit operate?

Check to see if other burners operate. If

so, check the gas orifice on the

malfunctioning burner for an obstruction.

Refer to Clean Burner Tubes and Burner

Ports on page 19. If problem still exists, 31ease call 1-800-913-8999.

Is the fuel hose bent or kinked?

Is the grill in a dusty area?

Is there adequate gas supply available?

If it is only one burner that appears low,

does the orifice or burner need cleaning?

Is the gas supply or gas pressure low?

19

Image 19
Contents Kenmoreo Sears Brands Management Corporation, Hoffman Estates, IL Grill Installation CodesIiiiii Proper Placement and Clearance of GrillRepair Protection Agreements Side Panel, Left 1pc Side Panel, Right Back panel Page Flat Head Screw 8mm Pcs Flat Washer @ .@ KEY# Parts Description Quantity JkY r Firebox Assembly Side Burner & Side Shelf Assembly B1. Use the two previously removed side burner Side Burner Valve AssemblyInstalling Cooking Components Grease Cup AssemblyBattery Assembly Congratulations Connecting LP Gas Tank to LP GrillGrill Lighting Instructions for Main Burners Checking for LP gas leaksManually Lighting Your Grill by Match Cleaning Exterior Stainless Steel Surfaces Annual Cleaning of Grill InteriorCleaning Burner Tubes and Burner Ports Vlvj-pII/,11lie Imle Jt,,e- II =1=vFlare-ups Cooking TemperaturesDirect Cooking Indirect CookingTemperature Time USDA* Safe Minimum Internal Temperatures FishMY-HOME