Electrolux 34942G operating instructions Burner

Page 13

Instructions for the Installer

 

BURNER

R A P I D

SEMI-RAPID

A U X I L I A R Y

T R I P L E

TYPE OF GAS

 

( l a r g e )

( m e d i u m )

( s m a l l )

C R O W N

 

 

 

 

 

 

 

 

 

 

 

POSITION

MAX

 

MIN

MAX

MIN

MAX

MIN

MAX

MIN

 

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

NATURAL GAS

POWER (kW)

3.0

0.65

2.0

0.45

1.0

0.33

4.0

1.2

 

 

 

 

 

 

 

 

 

 

20 mbar

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

VALUE =

RATE (m3/h)

0.286

0.057

0.190

0.038

0.095

0.028

0.381

0.114

37.78 MJ/m3

NOZZLE

 

 

 

 

 

 

 

 

 

Ws - 50.7 MJ/ m3

119

Adjust.

96

Adjust.

70

Adjust.

146

Adjust.

 

REFERENCE

 

(1/100 mm)

 

 

 

 

 

 

 

 

 

LPG GAS

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

28-30/37 mbar

POWER (kW)

2.8

0.65

2.0

0.45

1.0

0.33

4.0

1.2

VALUE=

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

49.92MJ/Kg

 

 

 

 

 

 

 

 

 

RATE (g/h)

202

43.5

144

29

72

21,5

252

86

 

 

NOZZLE REFERENCE

86

40

71

32

50

28

98

56

 

(1/100 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Dia. Tap By-pass

 

 

 

 

 

 

 

 

1/100 mm

Auxiliary28

Semi-rapid32

Rapid40

Triple-Crown 56

Aeration adjustment none

13

Image 13
Contents 34942G Installation Important Safety InformationChild Safety During UseEnvironmental Information ServiceContents Guide to Use the instructions Description of the Hob InstallationOperation Using the Wok StandHob burners control knobs Lighting the burnersHob Top Maintenance and CleaningPan Supports BurnersSomething Not Working? Symptom Solution0870 5 929 Service and Spare PartsStandard guarantee conditions Guarantee ConditionsEuropean Guarantee ExclusionsEngineers technical data Instructions for the InstallerBurner C a t i o n Important safety requirementsInstallation InstallationGas Connection Building Cut Out SizeBuilding over a cupboard or drawer Building over a kitchen unit with door Fitting the hob to the worktop SealThis HOB Must be Earthed Electrical connectionsPermanent Connection Wiring diagramPreliminary Electrical Systems Check Fault FindingEarth Continuity Check Check gas supply at burner Ignition System / Gas IgnitionCommissioning Pressure TestingMethod Conversion from Natural Gas to LPGPage From the Electrolux Group. The world’s No.1 choice