Electrolux 34942G operating instructions Wiring diagram, Permanent Connection

Page 21

Electrical connections

Permanent Connection

In the case of a permanent connection, it is necessary that you install a double pole switch between the hob and the electricity supply (mains), with a minimum gap of 3 mm. between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations.

The switch must not break the yellow and green earth cable at any point.

Ensure that the hob supply cord does not come into contact with surfaces with temperatures higher than 50 deg. C.

Replacement of the cable

The connection of the voltage cable to the appliance's terminal block is of type "Y". This means that its replacement requires the specific equipment of a technician.

In this case, only cable type H05RR-F must be used. The cable section must be suitable to the voltage and the working temperature.

The yellow/green earth wire must be approximately 2 cm. longer than the phase wires.

Wiring diagram

L

1

220 1

240

2

3

4

0 5

2

N

1.TAPS IGNITOR SWITCHES

2.IGNITOR UNIT

21

Image 21 Contents
34942G Installation Important Safety InformationChild Safety During UseEnvironmental Information ServiceContents Guide to Use the instructions Description of the Hob InstallationOperation Using the Wok StandHob burners control knobs Lighting the burnersHob Top Maintenance and CleaningPan Supports BurnersSomething Not Working? Symptom Solution0870 5 929 Service and Spare PartsStandard guarantee conditions Guarantee ConditionsEuropean Guarantee ExclusionsEngineers technical data Instructions for the InstallerBurner C a t i o n Important safety requirementsInstallation InstallationGas Connection Cut Out Size BuildingBuilding over a cupboard or drawer Building over a kitchen unit with door Fitting the hob to the worktop SealThis HOB Must be Earthed Electrical connectionsPermanent Connection Wiring diagramPreliminary Electrical Systems Check Fault FindingEarth Continuity Check Check gas supply at burner Ignition System / Gas IgnitionCommissioning Pressure TestingMethod Conversion from Natural Gas to LPGPage From the Electrolux Group. The world’s No.1 choice