Electrolux 34942G operating instructions Commissioning, Pressure Testing

Page 25

Commissioning

Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below.

1)Turn the gas tap to the MAX position and ignite.

2)Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below.

Procedure:

1)Re-ignite the burner and set to MIN.

2)Remove the control knob.

3)The adjustment screw is located down the centre of the gas tap control shaft.

To adjust, use a thin bladed screwdriver and turn the adjustment screw until the flame is steady and does not extinguish, when the knob is turned from MIN to MAX. Repeat this procedure for all burners.

FO 1042

a)Minimum adjustment screw

b)Tap

Pressure Testing

1)Remove left hand pan support and front left burner cap and crown.

2)Fit manometer tube over the injector.

3)Turn on the burner gas supply and ignite another burner supply.

The pressure reading should be nominally 20mbar and must be between 17 mbar and 25mbar.

4)Turn off the burner supplies.

25

Image 25
Contents 34942G Installation Important Safety InformationChild Safety During UseEnvironmental Information ServiceContents Guide to Use the instructions Description of the Hob InstallationOperation Using the Wok StandHob burners control knobs Lighting the burnersHob Top Maintenance and CleaningPan Supports BurnersSomething Not Working? Symptom Solution0870 5 929 Service and Spare PartsStandard guarantee conditions Guarantee ConditionsEuropean Guarantee ExclusionsEngineers technical data Instructions for the InstallerBurner C a t i o n Important safety requirementsInstallation InstallationGas Connection Building Cut Out SizeBuilding over a cupboard or drawer Building over a kitchen unit with door Fitting the hob to the worktop SealThis HOB Must be Earthed Electrical connectionsPermanent Connection Wiring diagramPreliminary Electrical Systems Check Fault FindingEarth Continuity Check Check gas supply at burner Ignition System / Gas IgnitionCommissioning Pressure TestingMethod Conversion from Natural Gas to LPGPage From the Electrolux Group. The world’s No.1 choice