Electrolux 34942G operating instructions Gas Connection

Page 16

Installation

FO 0814

FO 0264

A)End of shaft with nut

B)Washer

C)Elbow

On the end of the shaft, which includes the G 1/2" threaded elbow, adjustment is fixed so that the washer is fitted between the components as shown in the diagram. Screw the parts together without using excessive force.

Gas Connection

Connection to the gas supply should be with either rigid or semi-rigid pipe, i.e. steel or copper.

The connection should be suitable for connecting to RC 1/2 (1/2 BSP male thread).

When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation.

Ensure that the main connection pipe does not exert any strain on the hob.

It is important to install the elbow correctly, with the shoulder on the end of the thread, fitted to the hob connecting pipe.

Failure to ensure the correct assembly will cause leakage of gas.

16

Image 16 Contents
34942G Important Safety Information InstallationChild Safety During UseService Environmental InformationContents Guide to Use the instructions Installation Description of the HobUsing the Wok Stand OperationHob burners control knobs Lighting the burnersMaintenance and Cleaning Hob TopPan Supports BurnersSymptom Solution Something Not Working?Service and Spare Parts 0870 5 929Guarantee Conditions Standard guarantee conditionsEuropean Guarantee ExclusionsInstructions for the Installer Engineers technical data Burner Important safety requirements C a t i o nInstallation InstallationGas Connection Building Cut Out SizeBuilding over a cupboard or drawer Building over a kitchen unit with door Seal Fitting the hob to the worktopElectrical connections This HOB Must be EarthedWiring diagram Permanent ConnectionFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Check gas supply at burnerPressure Testing CommissioningConversion from Natural Gas to LPG MethodPage From the Electrolux Group. The world’s No.1 choice